Tuesday, June 21, 2016

What Is the Relationship Among the Alarm Indicators on the EFI Boards in OptiX OSN 6800 Subracks

This section describes the relationship among the alarm indicators on the EFI boards in OptiX OSN 6800 subracks.

Product

Fault Type

Other

Symptom

What is the relationship among the alarm indicators on the EFI boards in OptiX OSN 6800 subracks if the OptiX OSN 6800 NE adopts the master-slave subrack mode?

Cause Analysis

If the OptiX OSN 6800 NE adopts the master-slave subrack mode, the alarm indicators on the EFI boards in all the subracks are in the same state. That is, these alarm indicators indicate the alarm status of the entire NE rather than the alarm status of the individual subracks.

Procedure

  1. Suppress all the alarms reported by the boards in the master subrack of an OptiX OSN 6800 NE (assume that the boards in both the master and slave subracks report alarms). Then, check whether the alarm indicators on the EFI boards in the master and slave subracks are in the same state.
  2. Suppress all the alarms reported by the boards in the master and slave subracks. The alarm indicators on the EFI boards in all the subracks are off. Then, unsuppress the alarms reported by the boards in the master subrack. Check whether the alarm indicators on the EFI boards in all the subracks are in the same state.

Result

If the OptiX OSN 6800 NE adopts the master-slave subrack mode, the alarm indicators on the EFI boards in all the subracks are in the same state in case of an alarm reported by a board in either the master subrack or a slave subrack. That is, these alarm indicators indicate the alarm status of the entire NE.

No comments:

Post a Comment