The client equipment interconnected with the TOM board reports the R_LOS alarm due to a problem with the optical module on the TOM board.
Symptom
The SLQ4 board in the client equipment OptiX OSN 3500 interconnected with the TOM board in the OptiX OSN 6800 reports the R_LOS alarm. If you add an optical attenuator to the SLQ4 board, the alarm is cleared. In this case, the R_LOS alarm is reported again if you self-loop a client-side optical interface on the TOM board.
Procedure
- Replace the client-side optical module on the TOM board to check whether the module is faulty. The R_LOS alarm, however, persists after the module is replaced. This indicates that the module is normal.
- Configure the bidirectional services between a client-side optical interface on the TOM board and the client equipment. In this case, the R_LOS alarm is cleared.
- Consult the R&D engineers. They explain that the client-side optical module on the TOM board reports the R_LOS alarm instead of the R_LOF alarm upon receipt of all "0"s or all "1"s signals if no service is configured for the module.