Wednesday, June 22, 2016

The Existing Services Are Not Affected When the Fiber That Does Not Carry the Services in the Main Optical Path of That Traverses a Passive Board in a WDM Product Is Installed or Removed


The existing services are not affected when the fiber that does not carry the services in the main optical path that traverses a passive board in a WDM product is installed or removed.

Product

OptiX BWS 1600G, WDM, OSN6800,OSN8800

Fault Type

Other

Symptom

Are the existing services affected when the fiber that does not carry the services in the main optical path that traverses a passive board (such as the FIU) in the OptiX BWS 1600G equipment is installed or removed?

Cause Analysis

Based on the design specifications, the existing services are not affected when the fiber that does not carry the services in the main optical path that traverses the ITL, SCS, GFU, MR2, MB2, MR8, or FIU (E1/E2/E3) board is installed or removed.

Result

None.

Reference Information

This helps the on-site engineers in selecting the proper time to install or remove the fiber. Ensure that the correct fiber jumper is installed or removed. Otherwise, the existing services are affected.

When OptiX OSN 1800 Database Recovery Failures

No comments: