Boards Cannot Be Added on the NMS Due to Mismatch Between the NE Software Version and the NMS Version

The PL3A board cannot be added on the NMS because the NE software version does not match the NMS version. This fault is rectified by upgrading the NMS.

Fault Type

Others

Symptom

The PL3A board is installed in slot 11 of the OptiX OSN 1500B. This board, however, cannot be added on the NMS. The NMS version is T2000 V200R004 and the NE software version is 5.21.17.13.

Cause Analysis

Possible causes of the fault are as follows:
  • The NE software is incorrect.
  • The NMS is faulty.

Procedure

  1. Add the PL3A board in slot 11 by running commands. The board is added successfully, indicating that the NE software is normal.
  2. Query the version mapping table. It is found that the NE software version does not match the NMS version.
  3. Upgrade the NMS to T2000 V200R006. Then, the fault is rectified.