By default, the overseas parameters are configured according to the Chinese
standards. In the actual service configuration, the attributes such as the upper
and lower thresholds of the flash-hooking duration can be configured according
to the local standards to ensure that the response of the user terminal complies
with the local standards. Thunder-link provide OLT, MA5683T, MA5680T
Procedure
- Run the oversea parameters command to configure the overseas parameters.
- Run the display oversea parameters command to check whether the overseas parameters are the same as those in the data plan.
Example
To set the upper flash-hooking threshold (overseas feature parameter 0) to 800 ms (in compliance with the Hong Kong standard) and the lower flash-hooking threshold (overseas feature parameter 1) to 100 ms (in compliance with the Hong Kong standard), do as follows:huawei(config)#oversea parameters 0 800
huawei(config)#oversea parameters 1 100
huawei(config)#display oversea parameters
{ <cr>|name<U><0,99> }:
Command:
display oversea parameters
-----------------------------------------------------------------------------
Parameter name index: 0 Parameter value: 800
Mean: Hooking upper threshold(ms), reference: China:350, HongKong:800
-----------------------------------------------------------------------------
Parameter name index: 1 Parameter value: 100
Mean: Hooking lower threshold(ms), reference: China:100, HongKong:100
-----------------------------------------------------------------------------
Parameter name index: 2 Parameter value: 0
Mean: Flag of applying PARKED LINE FEED or not when user port is locked, 0:not
apply, 1:apply
-----------------------------------------------------------------------------
Parameter name index: 3 Parameter value: 0
Mean: The detect time of flash upper limit to onhook, default value: 0ms
-----------------------------------------------------------------------------
Parameter name index: 4 Parameter value: 0
Mean: DTMF Detector Tuning, 0:Q.24, 1:Russia
-----------------------------------------------------------------------------
Parameter name index: 5 Parameter value: 0
Mean: Flag of changing TEI value for software switch, 0:no change, 1:set TEI
value to 1, 2:set TEI value to 0. Default: 0
-----------------------------------------------------------------------------