Splicing of a G.652 Fiber with a G.655 or G.656 Fiber

The splicing of a G.652 fiber with a G.655 or G.656 fiber.

Product

OptiX BWS 1600G,OSN6800,OSN8800

Fault Type

Fiber

Symptom

A network adopts the OptiX BWS 1600G and with an RPC board as a Raman amplifier board. The customer uses G.656 fibers and the ODF interfaces are of the LC/PC type. By default, the RPC board of the OptiX BWS 1600G matches the G.652 fiber whose interface is of the FC/UPC type. The LC/PC interface of the fiber provided by the customer does not satisfy the requirements of high power. In addition, the FC/PC interface of a fiber is not available temporarily. After negotiation with the customer, direct splicing is adopted.

Cause Analysis

The effective sections of the G.652 fiber and the G.655 or G.656 fiber, technical specifications for manufacturers, and mode field diameters of the 1500 nm wavelength (the G.652 fiber is of a bigger diameter) are different.
When two G.652 fibers are spliced, a loss is produced. The average loss is 0.02 dB.
In the case of splicing of a G.652 fiber with a G.656 fiber, the loss is 0.38 dB due to different cross-sectional areas of fibers. In this case, the splicing loss is within the permitted range for an RPC board. In the case of splicing of a G.652 fiber and a G.656 fiber, the average loss is 0.5 dB. In the case of splicing of a G.652 fiber with a G.655 or G.656 fiber whose effective section is small, a great loss is produced (as great as 2 dB). In this case, the splicing loss is out of the permitted range.

Procedure

  1. None.

Result

The problem is resolved.

Sunday, July 10, 2016

How to Use the Ethernet Test Frames on the OptiX OSN 6800

This section describes how to use the Ethernet test frames on the OptiX OSN 6800.

Fault Type

Others

Symptom

None.

Cause Analysis

Using Ethernet test frames is a major method of determining whether the service configuration on a data board is correct. Certain boards intended for the OptiX OSN 6800 support this feature. The following section takes the LOG and TDG boards as examples to describe Ethernet test frames.
  • Whether electrical cross-connections need to be configured when the LOG board is used to test Ethernet services?
    Whether electrical cross-connections are configured does not affect the Ethernet service test on the LOG board. The LOG board can receive response test frames under the condition that optical path between the local and opposite LOG boards is available.
  • If the local and opposite TDG boards cross-connect services to the local and opposite LOG boards respectively, can the local TDG board receive response test frames?
    Electrical cross-connections are configured from the TDG board to the WDM side on the LOG board. The local TDG board cannot receive response test frames because the local LOG board also supports test frames. Even an inloop is performed at the optical interfaces on the WDM side of the local LOG board, the local TDG board cannot receive the test frames sent from the local TDG board.
    To enable that a TDG board receives test frames, cross-connect the services on the local TDG board to the local NS2 board, and then the opposite NS2 board cross-connects the services to the opposite TDG board. That is, electrical cross-connections must be configured when a TDG board tests the Ethernet services.

Procedure

  1. None.

Result

The problem is resolved.