How to Configure Two TMX Boards in a Client-Side 1+1 Protection Group Through an SCS Board

How to configure two TMX boards in a client-side 1+1 protection group through an SCS board.

Fault Type

Protection

Symptom

When configuring two TMX boards in a client-side 1+1 protection group through an SCS board, how to configure the attributes of the WDM interface ?
It is required to determine whether the Laser Status parameter should be set to Open and Automatic Laser Shutdown to Disabled, or Laser Status should be set to Open and Automatic Laser Shutdown to Enabled.
Is the laser on the TMX board closed automatically when the TMX boards work with an SCS board?

Cause Analysis

The setting of the Automatic Laser Shutdown parameter of the port on the WDM side or the client side is irrelevant to the protection. Normally, when the attributes of the WDM interface on the TMX board are configured through an OTU board, the Automatic Laser Shutdown parameter of the port on the WDM side is set to Disabled and Automatic Laser Shutdown of the port on the client side is set to Enabled.
After a client-side 1+1 protection group is configured, the status of the client-side laser is controlled by the status of protection group.

Procedure

  1. None.

Result

The problem is resolved.

Friday, June 3, 2016

The SC2 Board Reports the CRC4_CROSSTR Alarm

The SC2 board reports the CRC4_CROSSTR alarm due to the board faulty.

Fault Category

Optical Supervisory Channel Unit
CRC4_CROSSTR

Symptom

The SC2 board in the OptiX Metro 6100 reports the CRC4_CROSSTR alarm.

Cause Analysis

The main causes may be the abnormal received optical power and the fault in the fiber or optical connectors.

Procedure

  1. The received optical power of the SC2 board is normal (The receiver sensitivity of the SC2 board is -48V.), whereas the SC2 board reports the alarm.
  2. The fault persists even when the fibers and connectors at the RM1 interface of the SC2 board are cleaned.
  3. Replace the SC2 board, and the fault is cleared. This indicates that the RM1 interface of the SC2 board is faulty.