Wednesday, October 26, 2016

The Spectrum Analyzer Cannot Scan a Wavelength of the LWC Board Due to the Drift of This Wavelength

The spectrum analyzer cannot scan a wavelength of the LWC board due to the drift of this wavelength.

Fault Type

Optical Transponder Unit

Symptom

After one LWC board that operates at 192.9 THz is added to the OptiX Metro 6100 equipment on a network for capacity expansion, the MON port on the WBA board detects neither the 192.9 THz wavelength nor one more wavelength.

Cause Analysis

The possible causes of the problem are as follows:
  • The LWC board is faulty.
  • The WBA board is faulty.

Procedure

  1. Query the optical power at the IN optical port on the WBA board. The query result shows that the optical power at the IN optical interface after the expansion is the same as that before the expansion. This indicates that the added wavelength does not reach the WBA board.
  2. Use an optical power meter to test the LWC board. The test result shows that the output frequency of the board is 193.09 Hz. The WDM-side wavelength drift of the LWC board is large. Therefore, the wavelength of the LWC board does not match that of the M40 board interconnected with the LWC board.
  3. Replace the faulty LWC board and then test the output frequency at the MON interface on the new LWC board. The test result shows that the output frequency is within the normal range.

Result

After the faulty LWC board, the problem is solved.

Reference Information

Wavelength drift on the OTU board will cause low output optical power on the M40 board. Therefore, ensure that center frequency of each output wavelength on the WDM side of the OTU board is within the range of ±10 GHz from its nominal center frequency.

MORE BLOG:

When customized for North America unable to configure OSN1800.

Friday, June 3, 2016

Packet Loss Occurs in Ethernet Service Testing of the L4G Board

The packet loss occurs in Ethernet service testing of the L4G board due to the different equipment and meters.

Fault Type

Ethernet service

Symptom

In a test of EPL and VLAN networking by using the L4G board, the Smartbits meter is used to transmit complete bandwidth signals that are looped back on the client side at the remote end. During the test, a packet loss ratio of 0.001% is found. If the EPL networking is set up without the VLAN networking, no packets are lost on site.

Cause Analysis

In the EPL networking, exact synchronization of Ethernet networking can hardly be realized and a frequency deviation tolerance of +/-100 ppm is permitted. Hence, different equipment and meters trace different clock sources. If the inner oscillation frequency of the transmit unit is quicker than that of the receive unit, packet loss occurs.

Procedure

  1. None.