An NE Is Frequently Unreachable to the NMS Due to Insufficient Processing Capacity of a Router

An NE is frequently unreachable to the NMS due to insufficient processing capacity of a router.

Fault Type

NEs are unreachable.

Symptom

At a certain site, there are four WDM networks consists of 44 subracks of the OptiX BWS 1600G, two iManager T2000 servers, and the iManager T2000 clients on computers.
All equipment is GNEs. On the T2000, each network is configured with two gateways and an extended ECC is used for communication inside a network.
Each network is connected to a HUB with the T2000 server and client by a network cable. The 44 equipment is monitored by the T2000. T2000 displays that the NE communication is abnormal. NEs are unreachable randomly. In addition, the NE_COMMU_BREAK and NE_NOT_LOGIN alarms are reported and cleared automatically a certain while later. After multiple GNEs are configured on the T2000, the T2000 can re-monitor NEs temporarily. The problem occurs at a lower frequency; however, the problem is not resolved completely.

Cause Analysis

The possible causes of the preceding problem are as follows:
  • Equipment problems, such as a fault on the SCC board and improper ECC settings, may result in abnormal data flow.
  • NMS problems, such as an abnormal database, network card problems, and improper NMS settings.
  • DCN networking problems, such as incorrect network of the DCN, a fault on a router or switch, and network cable problems.
After an analysis, it is concluded that before the IP address of Sever 2 is changed, the 44 subracks of the four WDM systems cannot communicate with Server 2 by the switch directly. Because the IP addresses of the subracks are 132.37.23.**, while that of Server 2 is 132.37.5.**, the subracks and Server 2 are not in a same segment. Thus the subracks cannot communicate with Server 2 by a switch directly. The four WDM networks are monitored by Server 2. In this case, the data flow direction is: the equipment<--->the switch<--->the router<--->the switch<--->the server. There are 140 NEs in the four networks. Thus, the data flow is heavy and all data is forwarded by the router. The router, however, a 2630E router of an early age and with low-end technology, is configured with only one FE port. Communications of the two proceeding segments are forwarded through the IP addresses (of the two segments) configured at the same EO port. The bottleneck of the processing capacity of the router causes the network communication abnormality. Communications may be normal when the data volume is small. Once the data volume is larger, congestion of data packets is serious. As a result, NEs are unreachable. After the IP address of Server 2 is changed, the IP address of Server 2 and those of the added four DWDM systems are in the same segment. In this case, the data flow direction is: the equipment<--->the switch<--->the server. The communication between the four systems and Server 2 is implemented by the switch only and router forwarding is no longer required in the communication, thus greatly easing the processing load of the router and avoiding the bottleneck of the processing capacity of the router. The networks are smoother. Thus the preceding problem is resolved.
As a network becomes larger and more equipment is added in the network, the network structure is more and more complicated. If a network is lack of an overall planning at the early stage, communication problems at the later stage are of a great possibility. In addition, some causes for communication problems are difficult to detect, some causes are on the equipment, NMS, or network environment and need to observe for a period to see whether a processing step is effective after the processing step is performed. This consumes a lot of time and efforts. Therefore, at the early stage of project planning, not only service requirements but also the DCN network environment (such as the configuration, module and processing capacity of the router) should be taken into account.

Procedure

  1. In an early DCN structure, equipment and servers are connected through a HUB. In the HUB, data packets are broadcasted. This makes a bottleneck of processing capacity of the HUB. In addition, when running a ping command to the equipment, obvious packet losses occur in the HUB. Therefore, it is preliminarily suspected that the HUB is faulty. After replacing the HUB with a Layer 2 24-port switch, the equipment can be connected by running a remote ping command. Large packets are normal and CML tools can log in to NEs. The operation is improved; however, the problems that NEs are unreachable randomly last in Server 2. In System A, the problems are serious and certain sites can be hardly logged in to. Then a conclusion is inferred preliminarily that the HUB has certain impact on the NE communication, but it is not the main cause of the problems. Problems in System A are much more serious than that of other three systems. Therefore, it is suspected that the settings of a certain ECC or a network cable connection is faulty in System A.
  2. After the settings of ECC and routing of network cables in System A are checked, T2000 restores the monitoring on NEs. But after a few days' observation, the problems that NEs are unreachable for a long time are reduced obviously. Alarms, that are reported on the T2000, such as an NE_COMMU_BREAK alarm indicates that the NE communication is interrupted and an NE_NOT_LOGIN alarm indicates that an NE is not logged in to, however, indicate that NEs of all systems are unreachable transiently in Server 2. Thus a conclusion is inferred that the settings of ECC and routing of network cables in System A have certain impact on the NE communication, but are not the main cause of the problems. Problems in Server 1 which is located in the same equipment room as Server 2 are rare. Therefore, it is suspected that Server 2 is faulty.
  3. Upload the data of certain NEs of the four systems to Server 1 and observe the operation. In addition, re-install the operating system in Server 2 and re-install the T2000. In the next few days of observation, however, it is found that alarms indicating unreachable NEs transiently are not cleared in Server 2 and alarms indicating that the added NEs are unreachable are reported in Server 1. It is inferred that Server 2 is not faulty and is not the main cause of the problems. On Server 1 which is located in the same equipment room, original NEs are reachable and only the newly added NEs are unreachable frequently. In addition, the IP addresses of the four systems are not in the same segment with those of the two servers or old equipment. Therefore, it is suspected that the router is faulty in forwarding.
  4. According to analyzed on site by specialists in data communication and analyses with development engineers in optical network on related data in the T2000 logs, it is found that the main cause for the problems (NEs are unreachable) is network congestion. The data that the T2000 transmits to NEs cannot be sent out in time, which also proves the inference in Step 3. The forwarding capacity of the router may be insufficient, which resulting in congestion. Packets cannot be sent out in time. Thus, NEs are unreachable.
  5. Change the IP address of Server 2 (132.37.23.254), subnet mask (255.255.255.128), gateway (132.37.23.129) to make sure that the IP addresses of the server and added equipment are in the same segment. In this case, the communication between the equipment and T2000 is implemented directly by the switch and no router forwarding is required. After the modification, all the NEs in the four systems can be re-monitored normally. In the observation for a week, the alarms indicating that NEs are unreachable transiently are completely cleared.

Result

The problem is resolved.

Communication Anomaly Occurs Between the Equipment and the NMS Due to the Setting of the Firewall

If the equipment and the NM server communicate unidirectionly, disable the firewall or antivirus software to restore the communication.

Product

Fault Type

  • DCN fault

Symptom

During the system commissioning, it is found that the NM server can communicate with the OptiX OSN equipment by using the ping command, but the PC used on the equipment side cannot communicate with the NMS.

Cause Analysis

The firewall or antivirus software is used on the NM server.

Procedure

  1. Replace the NM server with a PC, and use the ping command to test the DCN. The result shows that the communication is normal.
  2. Disable the firewall or antivirus software on the NM server. The equipment side can communicate with the NM server by using the ping command.

How to do when Failing to Connect the 155 Mbit/s Optical Port on the Router of Company C

Friday, July 22, 2016

Querying the Physical State of a POTS Port

This topic describes how to verify whether a POTS port is in the normal state by querying the physical state of the POTS port on the NMS.

Prerequisites

  • The user is a user with the operator authority or higher.
  • The OLT and the NMS communicate with each other properly.
  • The NMS is able to discover an online ONT and VoIP service parameters are configured.

Procedure

  1. In the Main Topology, double-click the required OLT in the Physical Root navigation tree; or right-click the required OLT and choose NE Explorer from the shortcut menu.
  2. Choose GPON > GPON Management from the navigation tree.
  3. On the GPON ONU tab page, set the filter criteria or click  to display the GPON ONUs.
  4. Select a required record from the ONT list, and then click the Current ONU: UNI Port Info tab in the lower pane.
  5. View the icons in column Status, as shown in the following figure. You can see the icon meanings directly.

More blog:

What's the PPPoE Dialup Emulation?

After enabling PPPoE dialup emulation, you can emulate PPPoE dialup on the ONT and locate faults.

Prerequisites

  • The user is a user with the operator authority or higher.
  • The OLT and the NMS communicate with each other properly.
  • PPPoE users are configured on the BRAS.
  • The NMS is able to discover an online ONT and data of the Internet access service is configured.

Context

Currently, the mainstream access mode of broadband users is PPPoE dialup. In this mode, all service packets are encapsulated in PPPoE packets and PPPoE dialup authentication is terminated on the BRAS. The ONT is usually deployed on the edge of a network and resides between PPPoE dialup users and the BRAS, connecting PPPoE users to the network.
With the PPPoE dialup emulation function enabled on the ONT, you can emulate PPPoE dialup for testing and report collected test results to the NMS server. After analyzing the test result on the NMS server, you can determine where a fault occurs, which is very useful for daily maintenance and troubleshooting.

Procedure

  1. In the Main Topology, double-click the required OLT in the Physical Root navigation tree; or right-click the required OLT and choose NE Explorer from the shortcut menu.
  2. Choose GPON > GPON Management from the navigation tree.
  3. On the GPON ONU tab page, set the filter criteria or click  to display the GPON ONUs.
  4. Select a record from the ONT list, right-click, and then choose Test > PPPoE Test.
  5. In the dialog box that is displayed, set the related PPPoE emulation parameters, as shown in the following figure.
  6. Click Start. After the test is complete, test results are displayed on the NMS.

More blog:

What's the Optical Power Meter?

 This topic describes the appearance, functions, and usage instructions of the optical power meter.
The optical power meter is a necessary test meter for testing an optical fiber communication system. It is mainly used to measure the optical power of various wavelengths at multiple measurement points of an optical link. Optical power indicates the energy of the light at a measurement point of an optical link and is an important index of the optical fiber network. When the optical power is smaller than a specified value, the optical receive end will fail to detect optical signals. In other words, the optical receive end cannot receive the signals sent from the transmit end. Hence, it is important to use the optical power meter correctly.
The following considers EXFO's PPM-350B optical power meter as an example to describe how to use an optical power meter. (Other dedicated optical power meters for PON are used in a similar way.)
The PPM-350B optical power meter can measure the optical power of various wavelengths, including 1310 nm, 1490 nm, and 1550 nm in the GPON network. Figure 1 shows the appearance of the PPM-350B optical power meter.
Figure 1 Appearance of the PPM-350B optical power meter 
As shown in Figure 1, the PPM-350B optical power meter is different from common optical power meters. Specifically, the PPM-350B has a downstream input optical port and an upstream input optical port and can display the optical power of three wavelengths: 1310 nm, 1490 nm, and 1550 nm.
Figure 2 shows the common measurement points.
Figure 2 Measurement points of the optical power in the GPON network 
Maintenance engineers should also know related optical specifications on the ONT side, such as the maximum output optical power of the 1310 nm wavelength, minimum input optical power of the 1490 nm wavelength, and receiver sensitivity of the 1490 nm or 1550 nm wavelength. Table 1 lists the optical specifications on the ONT side.
Table 1 Optical specifications of optical ports on GPON ONTs
Parameter Type
Wavelength (nm)
Unit
Min.
Max.
Upstream data
1310
dBm
+0.5
+5
Downstream data
1490
dBm
-27
-8
Downstream CATV
1550
dBm
-8
+2
To use an optical power meter, do as follows:
Connect optical fibers to optical ports correctly in upstream and downstream directions.
Turn on the power supply.
Choose the measurement unit (dB or dBm).
Perform the measurement.
Figure 3 shows the measurement interface of the optical power meter.
Figure 3 Measurement interface of the optical power meter 
Optical channel loss is the total insertion loss caused by optical fibers, optical splitters, optical fiber connectors, and fiber connection points. Table 2 shows the estimation of optical channel loss in the engineering design.
Table 2 Optical loss parameters in engineering
Item
Average Loss (dB)
Connection point
Connector
0.3
Mechanical splicing
0.2
Fusion splicing
0.1
Optical splitter
1:64
19.7
1:32
16.5
1:16
13.5
1:8
10.5
1:4
7.2
1:2
3.2
Optical fiber (G.652)
1310 nm (1 km)
0.35
1490 nm (1 km)
0.25
Optical channel loss = L x a + n1 x b + n2 x c + n3 x d + e + f (dB)
 NOTE:
a indicates the average loss of an optical fiber per kilometer (unit: dB/km). L indicates the total length of the optical fiber (unit: km). The loss of patch cords and pigtail fibers used in engineering can be ignored because they are usually very short.
b indicates the loss of a fusion splicing point (unit: dB) and n1 indicates the number of fusion splicing points.
c indicates the loss of a mechanical splicing point (unit: dB) and n2 indicates the number of mechanical splicing points.
d indicates the loss of a connector (unit: dB) and n3 indicates the number of connectors.
e indicates the loss of an optical splitter (unit: dB). Only 1-level optical splitting is considered here. In the case of 2-level optical splitting, the loss of two optical splitters must be considered.
f indicates the engineering margin. Generally, the value is 3 dB.



More blog:

What is the command lines that we can use on the OLT to detect PRTE board status

Wednesday, July 20, 2016

Huawei S1700 series switch products debut, high performance network to help the construction of small and medium-sized enterprises

A leading telecom solutions provider Huawei in 2013 Ansett letter Partner Conference launched four new type S2700 series enterprise switch products (gigabit network management POE switches S1700-10GF-2P-PWR, S1700-28GFR-4P-PWR, Ethernet network management POE switch S1700-28FR-2T2P-PWR, Gigabit network switch without S1700-24GR). The new products are mainly aim at the small and medium-sized enterprise users, in addition to enhance the functionality and performance, especially optimize the convenient operation , attention by the majority of partners in the field.
With the arrival of the era of Gigabit Ethernet, small and medium-sized enterprise access switch forwarding capability and safety performance is bound to face challenges. Comparison of S1700 and similar products, has a higher packet forwarding, multi-service access ability, good expansibility, QoS (Quality of Service), a powerful guarantee multicast replication capacity and operational reliability, and can be widely applied to small and medium-sized enterprises, Internet cafes, hotels, schools, Ethernet access scene.
In the market of small and medium enterprises, the user for convenient and easy to use attention have different emphasis than the professional market, can provide “fool” operation more vulnerable to small and medium enterprises. This second congress commercial distribution of new S1700 series of enterprise switches display area is Huawei launched a new generation of green energy-saving switch, convenient management and maintenance methods, PC of simple operation, “one-click” button. At the same time provide function of traffic statistics based on the interface, support for IP network fault detection and location technology. In addition, S1700 is an intelligent PoE (Power over Ethernet) function, can provide low power supply to meet the data communication function at the same time, direct power supply for terminal, terminal no longer need wiring problem considering the power system, in the access network at the same time can be achieved for electrical equipment.
In the unified Internet Pavilion in this meeting, the enterprise core switch S9700 series as T bits high performance routing and switching machine during the same period at. S9700 for millions of megabytes of data exchange platform design, support the industry’s highest density of 8 × 40GE, 48 × 10GE high-density line speed card, 3.84T exchange capacity, can support the smooth expansion to 5.12T or 7.68T, and high density Gigabit / Gigabit port line speed forwarding. S9700 supports CSS (Cluster Switch System) switching network cluster and the service port cluster technology, the device virtualization is a logical device, has a strong advantage in reliability, flexibility and manageability aspects.
From S9700 series to the S1700 series, Huawei can provide coverage from the high-end to low-end series switch products and solutions, Huawei invests the switch products research and development long-term, at present in the enterprise network market has achieved outstanding performance, according to the statistics report industry authoritative analysis mechanism to the latest release of the Dell’oro in 2012: Huawei switch market is third largest on the world, grew more than 42%, and to maintain a sustained growth momentum.

More blog:

How to Delete a Console Login Password?

Huawei switch shows global competitiveness, global market share steadily

In 2012, the global Ethernet switch market by networking, cloud computing industry development drive, continue to show steady growth trend. Ethernet switch is still the mainstream market, intelligent switch is becoming the new development direction of exchange market. Through the Infonetics Researc released the latest report, in 2012 4.7% growth in global Ethernet switch sales revenue, the fourth quarter of 2012 Ethernet switch sales revenue growth of 5%.
According to IDC, in the fourth quarter of 2012, Cisco although in Ethernet switch market still occupy the dominant position, but the market share has declined, and the loss of market share is gradually digest the Huawei Huawei, gradually expand its market share, market share steadily rising trend. And in the Dell’oro recently released a report, in 2012, Huawei in global exchange market share has been ranked third. Huawei has become one of the market share of the global exchange market mainstream competitors in a higher increase of the enterprises in 2012.
In a recent Gartner report data shows, Huawei in switch market manufacturers share in 2011 from 10 in 2012 rose to fifth outside. The report data display, Huawei in 2012 fast growth rate, mainstream competitors list from the non-mainstream competitors in a short span of 1 years. And Huawei continues to strengthen its competitiveness in the market, to seek in the growth trend in 2013 continued to maintain the company in the market.
On the other hand, in the market, brand attention pattern and changed little in 2011, in the first tier market top brand user attention more focused, the first echelon manufacturers further deepened the influence on the market. In the second tier manufacturers to fierce competition, mutual gap small, but has little effect on the market influence.
Display through the Internet Consumer Research Center recently released report, the exchange market, Huawei’s brand awareness in the past three months were all above 20%, ranked second. Huawei is working with the first attention quickly narrow the gap, and there are indications that in the next few months Huawei will overtake market has become the focus of the first.
Huawei attention in exchange market is rising day by day, high quality products are mainly benefited from the Huawei Huawei, S5700-24TP-SI (AC) products continue to pay attention to product the first absolute advantage, and it is worth mentioning that, in the products concerned before ten, Huawei has six products on the list, in the market competition, both from a single product focus ratio or from a high degree of concern the number of products, Huawei in the market to maintain absolute superiority.
In the future, driven by 40GE, data center, BYOD application and other factors, the global exchange market still has certain development potential can be dug according to depth of industry manufacturers. In the future development of the market, exchange market core growth still comes from 10GE and 40GE films, but by the edge of deployment requirements school and network increases day by day, Gigabit Ethernet requirements and attention are also greatly enhance. On the other hand, the virtual data center Ethernet switch will drive demand for more intense, the above factors will become a powerful driving force exchange market development, and will further expand the market rise space.
As the Huawei cutting-edge HG532d based on carrying on the family of excellence performance, have a more powerful WIFI coverage and 270 degrees vertical wall performance. At the same time, the higher level of security, hacker intrusion protection system, super compatible with stability and white “ease of use makes it more as diocesan. The charm of elegant posture design also gives the HG532d more clear “soul”, carrying the user thought, preferences and beautiful home life.


More blog:

What is the command lines that we can use on the OLT to detect PRTE board status