Monday, January 23, 2017

The MSTP Configuration of stp md5-key

Function

The stp md5-key command is used to set the MD5 key for the MD5 encryption algorithm in an MST region. When you need to encrypt the region to ensure the device security, run this command. After the MD5 key for the MD5 encryption algorithm in the region is set, two devices cannot communicate with each other unless their MD5 keys are the same.
The undo stp md5-key command is used to restore the default MD5 key for the MD5 encryption algorithm in the region. The default MD5 key is recommended. After the MD5 key is modified, you can run this command to restore the default MD5 key. After the default MD5 key for the MD5 encryption algorithm in the region is restored, the MD5 key is 0x13AC06A62E47FD51F95D2BA243CD0346.

Format

stp md5-key number
undo stp md5-key

Parameters

Parameter Description Value
number Indicates the encryption parameter. The string must be hexadecimal and in length of multiples of 2. Character string type, a string of 1-32 characters.
Default: 0x13AC06A62E47FD51F95D2BA243CD0346
Recommended value: 0x13AC06A62E47FD51F95D2BA243CD0346.

Modes

Global config mode, OSN 1500, OSN 2500

Level

Operator level

Usage Guidelines

  • For the device security, two devices in a same region cannot communicate with each other unless their MD5 keys are the same. Thus, it is recommended to use the default MD5 key in the settings.
  • Two devices that belong to a same MST region must meet the following requirements:
    • The MST region names are the same.
    • The revision levels of the MST region are the same.
    • The configuration digest are the same. The configuration digest is calculated by using the MD5 encryption algorithm based on the VLAN mapping table of all configured spanning trees in the MST region and the MD5 key.

Example

To set the MD5 key for the MD5 encryption algorithm in an MST region to 00e0fc042958, do as follows:
huawei(config)#stp md5-key                                                      
{ string<S><Length 1-32> }:00e0fc042958                                                
                                                                                
  Command:                                                                      
          stp md5-key 00e0fc042958
To restore the default MD5 key for the MD5 encryption algorithm in an MST region, do as follows:
huawei(config)#undo stp md5-key   

Tuesday, April 26, 2016

Timeslot Collision Occurs When Service Is Created

An incorrect VC-12 timeslot numbering scheme is used. Therefore, timeslot collision occurs when a VC-3 service is created. Hence, you need to perform the service configuration according to the selected VC-12 timeslot numbering scheme when creating a VC-12/VC-3 service.

Product

Fault Type

Others

Symptom

Create VC-12 services 1 to 15 one after another in the STM-1 frame. Then, create a VC-3 service in the second VC-3 of the STM-1 frame. It is found that an alarm is generated to report the timeslot collision.

Cause Analysis

The sequential mode (ITU-T) is used as the VC-12 timeslot numbering scheme. Hence, the 15 VC-12 services occupy the second VC-3. Then, timeslot collision is reported when you create the VC-3 service in the second VC-3.

Procedure

  1. Right-click the NE on the T2000 and select Service Configuration.
  2. According to the service configuration and engineering planning, click Option and select ITU-T or Interleaved as the VC-12 timeslot numbering scheme.
  3. Create the services according to the selected VC-12 timeslot numbering scheme.

Reference Information

When you create a VC-12/VC-3 service on the T2000, configure the service according to the selected VC-12 timeslot numbering scheme. The following VC-12 timeslot numbering schemes are available:
  1. Sequential mode (ITU-T): The VC-12 timeslots that are numbered 1, 4, 7, 10, and so on belong to the first VC-3, the VC-12 timeslots that are numbered 2, 5, 8, 11, and so on belong to the second VC-3, and so on.
  2. Interleaved mode: The VC-12 timeslots numbered 1 to 21 belong to the first VC-3, and the VC-12 timeslots numbered 22 to 43 belong to the second VC-3, and so on.

More related:

Sunday, April 10, 2016

Warning of Service Interruption on a Multiplex Section

Warning of Service Interruption on a Multiplex Section Resulted from Simultaneous SD Clearing in OptiX NGSDH and OCS Products

Product Family: MSTP      Product Model: OSN 1500/OSN 2500/OSN 3500 II/OSN 7500

[Problem Description]
Triggering conditions
SD conditions at the two ends of a span on the same MSP ring are simultaneously cleared.
Symptoms
After SD conditions are cleared, some sites on the MSP ring do not recover and APS-INDI does not end.
Services on the MSP ring are interrupted.
Identification method
When an NE meets the following conditions, the problem addressed in this document occurs on the NE:
1. The NE runs a version specified in the preceding table, and ring MPS is configured for the NE.
2. After SD conditions are cleared, some sites on the MSP ring do not recover and APS-INDI does not end. In addition, services on the MSP ring are interrupted.
3. K bytes 0x8xxx, 0x5xxx, and 0x0xxx are cyclically sent during the period the problem persists. For details, see the following information:
#0x90406:cfg-get-rmsevent:1;
                                  MSSPR-EVENT-LOG                                 
    PG-ID  EVENT-NO  EVENT-VALUE     EVENT-PARA  DATE-TIME            TIME-STAMP  
    1      570       K_SENDS         0x512a      2012-4-29 12:33:15   0x022ebdd5  
    1      571       K_DIR           0x0002      2012-4-29 12:33:15   0x022ebdeb  
    1      572       STATE_TRANS     0x2405      2012-4-29 12:33:15   0x022ebe76  
    1      573       K_RECEIVED      0x0010      2012-4-29 12:33:15   0x022ebeb7  
    1      574       K_DIR           0x0002      2012-4-29 12:33:15   0x022ebebb  
    1      575       XC_EXECUTE      0x0200      2012-4-29 12:33:15   0x022ec323  
    1      576       K_SENDS         0x0020      2012-4-29 12:33:15   0x022ec3bf  
    1      577       K_DIR           0x0002      2012-4-29 12:33:15   0x022ec3d6  
    1      578       K_SENDS         0x0120      2012-4-29 12:33:15   0x022ec440  
    1      579       K_DIR           0x0000      2012-4-29 12:33:15   0x022ec450  
    1      580       STATE_TRANS     0x2100      2012-4-29 12:33:15   0x022ec4d3  
    1      581       K_RECEIVED      0x821a      2012-4-29 12:33:15   0x022ef3e3  
    1      582       K_DIR           0x0002      2012-4-29 12:33:15   0x022ef3e9  
    1      583       K_SENDS         0x1121      2012-4-29 12:33:15   0x022ef71e  
    1      584       K_DIR           0x0000      2012-4-29 12:33:15   0x022ef723  
    1      585       K_SENDS         0x8129      2012-4-29 12:33:15   0x022ef7aa  
    1      586       K_DIR           0x0002      2012-4-29 12:33:15   0x022ef7bf  
    1      587       STATE_TRANS     0x0408      2012-4-29 12:33:15   0x022ef846  
    1      588       K_RECEIVED      0x1212      2012-4-29 12:33:15   0x022ef8f9  
    1      589       K_DIR           0x0000      2012-4-29 12:33:15   0x022ef8fe  
    1      590       T2_START        0x0000      2012-4-29 12:33:15   0x022ef977  
    1      591       K_SENDS         0x5122      2012-4-29 12:33:15   0x022efa09  
    1      592       K_DIR           0x0000      2012-4-29 12:33:15   0x022efa0d  

Check whether a WDM device exists between the transmission devices and whether OLP is configured for the WDM device.

[Root Cause]
The SD condition on the site at one end of the span is cleared soon after the SD condition on the site at the other end of the span is cleared. The long path is long. As a result, the SD conditions are cleared between the time point at which a site receives the K byte sent on the short path and the time point at which the same site receives the K byte sent on the long path. Consequently, the same NE receives two different K bytes in the same direction. The standard does not provide a field in the K byte sent on the long path to specify whether the end responding to a fault is the end triggering a switchover or the end responding to a switchover. An NE sends a response as long as the request received on the long path differs from the local request. In the previously addressed scenario, the NE at either end receives two different requests from the long path and therefore responds to the requests because it considers that the opposite NE sends the requests, resulting in status flapping.

[Impact and Risk]
The MSP ring is not in the normal state and its carried services are interrupted.

[Measures and Solutions]
Recovery measures
Restart the multiplex section protocol throughout the ring.
Workarounds
Workaround 1: Do not use SD as a condition to trigger an MSP switchover.
Advantage: When SD occurs, the problem addressed in this document does not occur.
Disadvantage: If SD affects services, it will occur on links. Then, services are interrupted, and no protective switching is triggered.

Workaround 2: Do not use SD as a condition to trigger an MSP switchover. Reduce the SF threshold to the current SD value.
Advantage: When SD conditions at the two ends of a span are simultaneously cleared, the problem addressed in this document does not occur.
Disadvantage: If SD occurs on multiple sites on the same MSP ring, multiple SF switchovers occur. As a result, isolated areas occur, resulting in multiplex section squelching and service interruption.


Workaround 3: Set the MSP hold-off time (applicable to scenarios with OLP configured).
Advantage: If OLP triggers a switchover for the intermediate WDM device, no MSP switchover will occur. Therefore, the problem addressed in this document does not occur.
Disadvantage: If the hold-off time is set to 100 ms and no OLP switchover is triggered, an MSP switchover takes about 150 ms, which exceeds the allowed time.


Preventive measures
OCS:
Upgrade NEs involved to V1R6C03SPC200+SPH206 or a later V1R6C03 version or V1R6C05SPC201 or a later version.
NGSDH:
For NEs running V100R008C02SPC500, install SPH505 or a later patch version.
For NEs running V100R008C02SPC200, install SPH203 or a later patch version.
Upgrade NGSDH NEs running V100R009 or V100R010 to V100R010C03SPC203 or a later version.
Upgrade NGSDH NEs running V200R011 or V200R012 to V200R012C01 or a later version.
Material handling after replacement
None

[Inspector Applicable or Not]
None

[Rectification Scope and Time Requirements]
None

[Rectification Instructions]
None

[Attachment]
None


More related:

Warning of Unexpected NE Resets Resulted from Resetting Boards Without a CPU on MSTP NEs