Saturday, June 11, 2016

The Cross-Connection Function of the Subrack Fails



The cross-connection function between two LOG or ELOGS boards on the left and right sides of the subrack fails because the hardware bus is restricted.

Fault Type

Optical Transponder Unit
Subrack

Symptom

The cross-connection function between two LOG boards on the left and right sides of the subrack fails. Relevant documentation, however, shows that the LOG board supports the function.

Cause Analysis

The hardware bus is restricted. The backplane of the OptiX Metro 6100 V100R006 subrack consists of two parts, that is, slots IU1-IU6 and slots IU8-IU13. The two LOG or ELOGS boards can be configured with the inter-board GE service cross-connection and the WXCP protection if the two boards are both installed in slots IU1 and IU3 or IU8 and IU10.
The ELOG or ELOGS board supports the inter-board GE service cross-connection across cross-connect planes.
  • The combination of two ELOG or ELOGS boards in the same cross-connect plane (in slots IU1-IU6 or slots IU8-IU13) supports the cross-connection of a maximum of eight pairs of GE services.
  • The combination of two ELOG or ELOGS boards in two paired slots (IU1 and IU8, IU2 and IU9, IU3 and IU10, IU4 and IU11, IU5 and IU12, or IU6 and IU13) also supports the cross-connection of a maximum of eight pairs of GE services.

Procedure

  1. None.

Line Reflection Leads to Inaccurate BER Detection of the SSC6LWX Board, the Board Reports the B1_EXC Alarm

The line reflection leads to the inaccurate BER detection of the SSC6LWX board. The board reports the B1_EXC alarm.

Fault Type

Optical Transponder Board
Bit Error
B1_EXC

Symptom

As shown in Figure 1, when an intensive reflection exists on the line, the SDH instrument reports bit errors. When the performance event reporting of the LWX board along the signal flow is queried, however, the first bit error reporting point is found on the RX port of the downstream board 2 instead of on the IN port of board 1. Alternatively, the IN port of board 1 has only a few bit errors, whereas plenty of bit errors appear on the RX port of board 2. Such a phenomenon in which the first bit error reporting point is on the second receiving side in the downstream instead of on the first receiving side is called "beating an ox on the other side of a mountain". The phenomenon, caused by line reflection, directly impacts the fault analysis and troubleshooting and misleads the fault locating on site. By now, the problem has occurred in two sites.
The LWX board reports the B1_EXC alarm.
Figure 1 Networking diagram

Cause Analysis

As shown in Figure 2, the LWX is a wavelength conversion board of any rate ranging from 32 Mbit/s to 2.5 Gbit/s. The board implements performance monitoring through bypass detection. That is, it divides the received signals into two parts. One part is sent to the performance monitoring module for bit error statistics, and the other part is sent to the downstream chip for output after being processed by the board. Because the performance monitoring path is independent of the signal output path, it is possible that the receiving side of the board is normal but bit errors occur after board processing. Because the LWX is an access board of any rate ranging from 32 Mbit/s to 2.5 Gbit/s, no phase-locked loop circuit exists inside the board. Nevertheless, the performance monitoring module is implemented by the FPGA. Depending on the service type monitored, the board is loaded with a specific logic file. A phase-locked loop (that is, access at a fixed rate) exists inside every implemented circuit. Hence, the two parts of signals differ in performance. Generally, this difference is ignorable. If no bit error occurs in performance monitoring, the signals received by the board on this point can be regarded normal; however, when the multipath interference (MPI) effect is triggered by an intensive reflection point on the line, the BER detection of the board may be inaccurate (inaccurate BER reporting of the board is the only reflection-caused problem found during the three years of application of the LWX board).
Figure 2 Working principle of the SSC6LWX board
To locate the preceding LWX bit error problem, the normal location method is preferred to check the optical power, OSNR, and dispersion of the system, which are found normal. Then, the software and hardware of the board are checked to ensure that the board is normal (these are the items that should be inspected first, and are the most easily discernible causes for the problem). After the foregoing factors are precluded, if the LWX still reports bit errors, the upstream line might be faulty. An OTDR is used to measure the line and check whether any intensive reflection event occurs, that is, whether intensive reflection point exists on the line (according to the China national standard, the reflection must be less than -27 dB). After the reflection point is found, the problem can be cleared by cleaning the fiber, replacing the connector, or splicing the fiber connector.
Because the interference light and signal light caused by reflection are in the same direction and at the same frequency, and impose little impact on the power of the main signal light, the problem is unable to be discerned by measuring the optical power of signals or the OSNR with the optical power meter or spectrum analyzer.

Procedure

  1. Use the OTDR instrument to measure the line and observe whether intensive reflection events occur on the instrument, and detect the reflection problem on the line.
  2. A research shows that the MIP effect greatly impacts the probability distribution of the "1" codes in the system. Based on the special optical power distribution generated by secondary reflection interference on the "1" codes of the signal light, the statistic function of the eye pattern tester can be used to test the optical power distribution diagram (histogram) of the "1" codes in the eye pattern. In this way, the existence of the secondary reflection interference can be discerned effectively.

Reference Information

Figure 3 shows the main signal eye patterns. Figure (a) shows the eye pattern when the secondary reflection interference does not exist; figure (b) shows the eye pattern when the secondary reflection interference exists.
Figure 3 Main signal eye patterns when the secondary reflection interference does not exist and exists



Wednesday, June 8, 2016

The Cross-Connection Function of the Subrack Fails



The cross-connection function between two LOG or ELOGS boards on the left and right sides of the subrack fails because the hardware bus is restricted.

Product

Fault Type
Optical Transponder Unit
Subrack

Symptom

The cross-connection function between two LOG boards on the left and right sides of the subrack fails. Relevant documentation, however, shows that the LOG board supports the function.

Cause Analysis

The hardware bus is restricted. The backplane of the OptiX Metro 6100 V100R006 subrack consists of two parts, that is, slots IU1-IU6 and slots IU8-IU13. The two LOG or ELOGS boards can be configured with the inter-board GE service cross-connection and the WXCP protection if the two boards are both installed in slots IU1 and IU3 or IU8 and IU10.
The ELOG or ELOGS board supports the inter-board GE service cross-connection across cross-connect planes.
  • The combination of two ELOG or ELOGS boards in the same cross-connect plane (in slots IU1-IU6 or slots IU8-IU13) supports the cross-connection of a maximum of eight pairs of GE services.
  • The combination of two ELOG or ELOGS boards in two paired slots (IU1 and IU8, IU2 and IU9, IU3 and IU10, IU4 and IU11, IU5 and IU12, or IU6 and IU13) also supports the cross-connection of a maximum of eight pairs of GE services.

Procedure

  1. None.

The SCC Board Reports the HARD_BAD Alarm

The SCC board reports the HARD_BAD alarm. When you query the version information about the BPA board and the GSCC board, you find that the version of the BPA board does not match the version of the GSCC board. After you upgrade the BPA board, the HARD_BAD alarm is cleared.

Product

Fault Type

HARD_BAD
Others

Symptom

The SCC board reports the HARD_BAD alarm. After the working and protection SCC boards are switched, the HARD_BAD alarm persists.

Cause Analysis

Check the HARD_BAD alarm on the T2000 to determine the slot of the faulty board and the cause of the fault.

Procedure

  1. Check the HARD_BAD alarm on the T2000. Location Information displays information about the board that causes the alarm. After you select an alarm on the T2000, the alarm location information is displayed in the lower left corner of the page.
  2. Check the software version of the board.
    1. Choose Report > Board Information Report from the Main Menu.
    2. Select the NE, and then click .
    3. Right-click a parameter name in Board Information Report and choose Software Version to display the software version of the board.
  3. Check the software version of the board, and you can find that the version of the BPA board does not match the software version of the GSCC board.
  4. Upgrade the BPA board. After the BPA board is upgraded, the HARD_BAD alarm is cleared.

The BA2 Board Reports an Abnormal Alarm

The BA2 board at station A reports an abnormal alarm. After the input optical wavelength is changed to the range from 1530 nm to 1560 nm, the fault is rectified.

Product

Fault Type

PUM_BCM_ALM
OUT_PWR_ABN
Others

Symptom

The OptiX OSN 1500 equipment at stations A and B form the 1+1 linear multiplex section protection (MSP). Station A contains the SLD4 board, the CXL4 boards (working and protection boards), and two BA2 boards. Station B contains the SLD4 board, the CXL4 boards (working and protection boards), and one BA2 board. The optical interface on the SLD4 board is of the Ve-4.2 type, and the optical interface on the CXL4 board is of the L-4.1 type. The output optical power of each BA2 board is +14 dBm. The distance between stations A and B is 120 km.
When the commissioning test is performed after the fibers are connected properly, the PUM_BCM_ALM and OUT_PWR_ABN alarms are detected on the two BA2-S boards of station A, but no alarm is detected on the BA2-D boards of station B.

Cause Analysis

The PUM_BCM_ALM alarm indicates that the driving current of the remote pump laser crosses the specified threshold. When the driving current exceeds the specified maximum working current, the PUM_BCM_ALM alarm is generated.
The OUT_PWR_ABN alarm indicates that the output optical power is abnormal. When the input optical power is within the specified range (BA: -6 dBm to +3 dBm; PA: -36 dBm to -10 dBm), no alarm is generated for the working current, and the working current is not adjusted, the output optical power exceeds the specified range (BA: +13 dBm to +15 dBm; PA: gain < 19 dB), the OUT_PWR_ABN alarm is generated. Generally, the following causes are possible. The EDFA module is aged or faulty. The driving circuit is damaged or the drive current detection circuit is faulty.

Procedure

  1. Check the performance value of one BA2-S board of station A on the T2000.
    1. Right-click the NE of station A in the Main Topology and choose NE Explorer.
    2. Select one BA2 board from the board list in NE Explorer.
    3. Select Performance > Current Performance from the Function Tree.
    4. Select Gauge in the right pane, and then select Transmitted Optical Power and Receive Optical Power. In Display Options, select Display Current Value.
    5. Click Query.
  2. Analyze the data. In the case of the BA2 board, the input optical power is -2.6 dBm, which is within the specified range (-6 dBm to +3 dBm); but the output optical power is +12.9 dBm, which is beyond the specified range (+13 dBm to +15 dBm). Hence, the OUT_PWR_ABN alarm is generated. In the case of the EDFA module, the specified maximum working current is 138 mA, but the actual working current is 188 mA. Hence, the PUM_BCM_ALM alarm is reported.
  3. Replace one BA2 board.
  4. Check the alarms on the T2000. If the OUT_PWR_ABN and PUM_BCM_ALM alarms persist, rectify the fault of the board.
  5. Check the fiber connection. At station A, the BA2 board is connected to the CXL4 board. The output optical wavelength of the CXL4 board ranges from 1280 nm to 1335 nm and is beyond the specified amplification range (1530 nm to 1560 nm) of the EDFA module. Hence, the input optical signals cannot be amplified properly.
  6. Remove the fiber jumper between the CXL4 board and the BA2 board.
  7. Connect the SLD4 board to the BA2 board by using fiber jumpers.
  8. Query the current alarms of the NE. The abnormal alarms are cleared automatically.

Related Information

In the project or maintenance work, the related specifications (such as the wavelength and power of the input optical signals and the power of the output optical signals of the BA2/BPA boards) must meet the specified requirements.
The working wavelength of the PA module is 1550.12 nm. When the working wavelength of the PA module is highly offset from 1550.12 nm, the offset value of the input optical power and output optical power is high. The normal input optical power ranges from -36 dBm to -10 dBm. If the input optical power is too high, the life of the laser may be shortened. If the input optical power is too low, the EDFA module cannot amplify the optical power properly.
The input working wavelength of the BA module ranges from 1530 nm to 1560 nm, which is the 1550 nm window wavelength. When the input working wavelength of the BA module is beyond the range, the BA module cannot amplify the input optical signals properly. The PUM_BCM_ALM and OUT_PWR_ABN alarms may also be generated. The normal input optical power of the BA module ranges from -6 dBm to +3 dBm. If the input optical power is beyond the range, an alarm is generated, indicating that the input optical power is abnormal. If the input optical power is too high, the life of the laser may be shortened.


More related:

Interconnection Between the OLT and the Switch Fails

Tuesday, June 7, 2016

No Optical Power Is Output on the WDM Side

No optical power is output on the WDM side of the LWM board due to incorrect configuration of the SFP module on the client side. The LWM board reports the R_LOF, R_LOC, TP_LOC alarms.

Product

OptiX Metro 6100
OptiX Metro 6040

Fault Type

Optical Transponder Unit
R_LOF
R_LOC
TP_LOC

Symptom

In a network, the LWM board accesses the STM-16 service on the client side but does not output optical power on the WDM side. In addition, the client side of the LWM board reports the R_LOF or R_LOC alarm, and thus the WDM side of the board reports the TP_LOC alarm.

Cause Analysis

The SFP module on the client side of the board is of SCP6801-H1-BNE and supports rates that are only lower than 155.52 Mbit/s. This SFP module does not comply with the specifications of the LWM board. Hence, this problem results from the incorrect configuration of the SFP module type.

Procedure

  1. Replace the SFP module of the correct type on the client side to clear the fault.

How to Configure the Dual Feed and Selective Receiving Boards

How to configure the dual feed and selective receiving boards in the case of a unidirectional WDM link.

Fault Type

Optical Transponder Unit

Symptom

The LDG board that supports the dual fed and selective receiving is used as the service board. This case also applies to the OTU board hat supports the dual fed and selective receiving.
When the link is not configured with protection and the fiber signal flow is not created on the T2000, the T2000 display that the WDM-side optical interfaces adopt two separated routes.

Cause Analysis

In the case of the board that supports the dual fed and selective receiving, if the physical fibers are not connected and the logic fibers are not created on the T2000, the system cannot identify whether the link is configured with protection.
To make the system report the correct WDM-side optical interface information (that is, the link does not adopt the intra-board 1+1 protection) of the LDG board, the use status of the unused WDM-side optical interfaces must be set to Unused.

Procedure

  1. In the NE Explorer, select the desired board, and choose the Configuration > WDM Interface.
  2. In Basic Attributes, select the Path Used Status field, and set the use status of the WDM-side optical interfaces to Unused.