Thursday, May 12, 2016

What’s the Line Encryption of GPON

Context

In the PON system, downstream data is broadcast to all ONUs. As a result, downstream data destined for certain ONUs or all ONUs may be intercepted by illegal users.
Figure 1 Downstream data transmit process 

Working Principle

Line encryption technologies are required to eliminate the data theft risk, Figure 2 shows line encryption process.
Figure 2 Line encryption process 
· The encryption algorithm to be used is the advanced encryption standard (AES).
· The 10G GPON systems use the AES-128 encryption algorithm.

Highlight and Application

· The line encryption algorithms neither increase overhead nor decrease bandwidth usages.
· The line encryption algorithms will not prolong transmission delays.
· Enable line encryption if the usage scenarios promote high security requirements

More related:

How to Control Board Failure After an MxU Service Port Is Bound to a Rate Unlimited


Tuesday, March 29, 2016

Warning of Failed Cascading on the MA5616 Equipped with the JDSU GE Optical Module


Keywords: MA5616, H831CCUC, JDSU (optical module vendor), GE optical module, GE optical port cascading, cascading failure
Summary: An MA5616 equipped with the H831CCUC control board uses the JDSU-provided GE optical module with BOM number 34060286 for upstream cascading. The cascading fails and the LINK indicator on the control board is not on.
Product Line: Access Network Product Line    Product Model: MA5616
[Problem Description]
Trigger conditions
Two MA5616s (equipped with H831CCUC control boards) use the GE optical port for cascading. The GE optical module is provided by JDSU and the BOM number is 34060286.
Figure 1 JDSU-provided GE optical module


Symptom
The cascading fails and the LINK indicator on the control board is not on.
Identification method
1. Perform the following three steps to verify that the device, optical link, and optical module are functional.
a Verify that the device is functional.
The device is powered on and displays information using the serial port. The system displays the message "Press any key to get started." Use the user name and password to log in to the device. Query the board information. The system displays "normal", indicating that the device and board are functional.
MA5616(config)#display board 0
-------------------------------------------------------------------------
  SlotID  BoardName  Status           SubType0 SubType1    Online/Offline
-------------------------------------------------------------------------
  0       H831CCUC   Active_normal    UP2A
  1
  2
  3
  4
  5       H831PDIA   Normal
  -------------------------------------------------------------------------

MA5616(config)#display board 0/0

  ---------------------------------------
  Board Name          : H831CCUC
  Board Status        : Active normal
  ---------------------------------------

  Subboard[0]: H831UP2A                        Status: Normal
  -----------------------------------------------------------------------------
  Port   Port   MAC              Register             Link    Role      Active
         Type                    State                State             State
  -----------------------------------------------------------------------------
     0  GE optic    normal    -      auto       auto     off   active   offline
  -----------------------------------------------------------------------------
  ------------------------------------------------------------------------------
  Port Port COMBO    Optic    MDI    Speed      Duplex    Flow- Active   Link
       Type Mode     Status          (Mbps)               Ctrl  State
  ------------------------------------------------------------------------------
     1 GE   -        absence  -      auto       auto      off   active   offline
  ------------------------------------------------------------------------------
  Note: For a 1000 M, electrical port in the full-duplex mode, setting MDI to
        any value is invalid
b Verify that the optical link is functional.
Ensure that an orange multi-mode LC/PC optical fiber is used. After the optical link starts to work, run the following command to query the transmit and receive optical power: (The range for the transmit optical power is –9.5 dBm to –2.5 dBm, and the range for the receive optical power is –17 dBm to 0.)
MA5616(config-if-eth-0/0)#display port ddm-info 1                                          
  Command:                                                                      
          display port ddm-info 1                                               
  Temperature(C)                       : 32.550000                              
  Supply voltage(V)                    : 3.300000                               
  TX bias current(mA)                  : 4.550000                               
  TX power(dBm)                        : -5.010000                              
  RX power(dBm)                        : -6.160000     
c Verify that the optical module is functional.
Verify that the optical module is free of any visible damage and is not removed. Insert the optical module to the optical port and run the following commands to verify that the optical module is functional:
MA5616(config)#interface eth 0/0
MA5616(config-if-eth-0/0)#display port opticstate 1
    Note: The type of optical module does not fully support the SFF-8472
standard. The queried information may be incorrect or unspecified
  Optics module information
    Identifier                        : SFP
    Ext.Identifier                    : GBIC/SFP function is defined by serial
                                        ID only
    Connector                         : LC
    Transceiver
      Infiniband compliance codes     : Invalid
      SONET compliance codes          : Invalid
      GE compliance codes             : 1000BASE-SX
      Link length                     : short distance
      Transmitter technology          : shortwave laser
      Transmission media              : multi-mode, 62.5m
      Speed                           : Invalid
    Encoding                          : 8B10B
    BR,Nominal                        : 2100 MBits/sec
    Length(9um)-km                    : 0 km
    Length(9um)                       : 0.0  km
    Length(50um)                      : 500 m
    Length(62.5um)                    : 300 m
    Length(Copper)                    : 0 m
    Vendor name                       : JDSU
    Vendor OUI                        : 412
    Vendor PN                         : PLRXPL-VI-S24-HW
    Vendor rev                        : 1
    Wavelength                        : 850 nm
    Cc_base                           : 0x7f
    Options                           : Invalid
    BR,max                            : Unspecified
    BR,min                            : Unspecified
    Vendor SN                         : CC17QQ322
    Date code                         : 12 04 18
    Diagnostic Monitoring Type        : Internally Calibrated
    Enhanced Options                  : Optional Alarm/warning flags implemented
                                        for all monitored quantities
    SFF-8472 Compliance               : Includes functionality described in Rev-
                                        10.2 SFF-8472
    CC_EXT                            : 0xec
    Vendor specific                   :
        20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
        20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
2. Check whether the LINK indicator on the control board is on. If the indicator is not on, the cascading fails.
3. Query the link status of the cascaded optical port. If the system displays "offline", the cascading fails.
MA5616(config-if-eth-0/0)#display  port  state all
------------------------------------------------------------------------------
Port Port COMBO    Optic    MDI    Speed      Duplex    Flow- Active   Link   
  Type Mode     Status          (Mbps)               Ctrl  State           
------------------------------------------------------------------------------
0      GE optic    normal    -      auto       auto     off   active   offline
1      GE   -      normal    -      auto       auto     off   active   offline
 ------------------------------------------------------------------------------
Note: For a 1000 M, electrical port in the full-duplex mode, setting MDI to  
        any value is invalid
----End
[Root Cause]
An error occurs when the JDSU-provided GE optical module is used with the H831CCUC control board. The LOS decision mechanism of the JDSU-provided GE optical module conflicts with that of the H831CCUC control board. As a result, the handshake fails, causing a cascading failure.
[Impact and Risk]
The MA5616 equipped with the H831CCUC control board is delivered with the JDSU-provided GE optical module (BOM number: 34060286). If the GE optical module is used for cascading, the cascading fails, affecting deployment.
[Measures and Solutions]
Recovery measures
None
Preventive measure
Configure the MAC chip register in the software.
Solution
Upgrade the control board to V800R310C00SPC103 on new sites in which the cascading is used.
[Attachment]
None
[Rectification Scope and Time Requirements]
None
[Prewarning Expiration Condition]
None


More blog:

What’s the IGMP Framework on the Device

Friday, March 25, 2016

How to Control Board Failure After an MxU Service Port Is Bound to a Rate Unlimited

Abstract: In MxU V800R306C01, V800R307C00, and V800R307C01, the MxU control board fails after the following operations are performed:
Product Line: Access network product line  Product Model: MA5616
l Create a rate unlimited traffic profile (traffic table ip) through the U2000 or N2000.
l Bind the traffic profile to a service port on the MxU.
Restart the MxU.

[Problem Description]

Trigger conditions:
This issue occurs after all the following requirements are met:
1. A rate unlimited profile is created on the MxU through the U2000 NMS.
2. The MxU version is V800R306C01, V800R307C00, or V800R307C01.
3. The created profile is bound to a service port on the MxU.
Symptoms:
After the MxU is restarted, the control board fails. As a result, service boards fail to register with the control board and the MxU cannot be managed by the NMS.
HUAWEI(config)#display board 0
  -------------------------------------------------------------------------
  SlotID  BoardName  Status         SubType0 SubType1    Online/Offline
  -------------------------------------------------------------------------
  0       H821EPUA   Active_failed                       Unmanageable
  1       H821EPFB   Failed                              Online   
  2       H821ASNB   Failed                              Online   
  -------------------------------------------------------------------------
Identification methods:
If a control board fails after the MxU is restarted, perform the following operations to determine that the fault is caused by the issue described in this pre-warning:
1. Verify that the MxU version is V800R306C01, V800R307C00, or V800R307C01.
2. Verify that a rate unlimited profile exists on the MxU and it is bound to a service port on the MxU.
The following configurations are used as an example:
traffic table ip index 7 name "NOCAR" cir off color-mode color-blind  priority 0 priority-policy local-setting
……
service-port 0 vlan 1049 eth 0/1/1 multi-service user-vlan untagged  rx-cttr 7 tx-cttr 7
service-port 1 vlan 1050 eth 0/1/2 multi-service user-vlan untagged  rx-cttr 7 tx-cttr 7
3. Query MxU last words. If the following highlighted error codes are displayed for l2qos files, the fault is caused by the issue described in this prewarning.
HUAWEI(su)%%display lastwords all
……
l2qos_traff  1315          0          0          1 0x7b0       0x7b0     
l2qos_traff  1316          0          0          1 0x9c4000   0x9c4000  
l2qos_traff  1317          0          0          1 0x9c4000   0x9c4000  
l2qos_traff  1424          0          0          1 0x68bafe   0x68bafe  

[Root Cause]

In MxU V800R306C01, V800R307C00, or V800R307C01, if a rate unlimited profile is created through the NMS, the MxU database may malfunction. The traffic profile cannot restore from the database after the MxU is restarted. In this case, if the traffic profile is bound to a service port on the MxU, the service port cannot find the traffic profile in the recovered data. As a result, the MxU hardware fails to be configured and accordingly, the control board fails.

[Impact and Risk]

The control board fails, services on the MxU fail, and the MxU cannot be managed by the NMS.

[Measures and Solutions]

Recovery measures:
Workarounds
1. If an abnormal traffic profile has been loaded to the MxU on the live network but the MxU has not been restarted, delete the traffic profile from the NMS and use a functional traffic profile.
2. If the MxU has been restarted and the control board fails, create the service port that is bound to the abnormal traffic profile on the MxU by running commands. Then, save the data.
The procedure is as follows:
Step 1: Run the display saved-configuration command to query the original configuration.
If a service port is bound to the abnormal traffic profile, change the traffic profile to a functional one.
The following configurations are used as an example, where traffic profile 7 is the abnormal profile:
HUAWEI(config)#display saved-configuration
[MA5600V800R305: 12301]
#
[global-config]
  <global-config>
 traffic table ip index 7 cir 51200 cbs 1024000 pir 102400 pbs 1024000  priority
 user-cos 0 priority-policy local-setting
#
[public-config]
  <public-config>
 snmp-agent local-engineid 800007DB0300E0FC112233
#
[vlan-config]
  <vlan-config>
 vlan 200
#
[bbs-config]
  <bbs-config>
 service-port 0 vlan 200 eth 0/1/1 user-vlan untagged  rx-cttr 7 tx-cttr 7
#
return
Step 2: Load the modified configuration file to the MxU or manually change the traffic profile ID to the one of a functional traffic profile.
The following manual configurations are used as an example:
service-port 0 vlan 200 eth 0/1/1 user-vlan untagged  rx-cttr 6 tx-cttr 6
Step 3: Create the service port with the preceding configurations by running commands.
Step 4: Save the data.
Preventive measures:
For the MA562X or MA5616, upgrade the version to V800R308C00SPC508 or later to resolve this issue.
For MA5620E V800R307 or MA5620G V800R307, the V800R312C00SPC205 is being developed, which resolves this issue and will be released in the end of 2013.
Solution:
For the MA562X or MA5616, upgrade the version to V800R308C00SPC508 or later to resolve this issue.
For MA5620E V800R307 or MA5620G V800R307, the V800R312C00SPC205 is being developed, which resolves this issue and will be released in the end of 2013.

[Warning Conditions]

The warning does not take effect when the trigger conditions are not met.

[Attachment]

None