Thursday, June 2, 2016

Repeated Clock ID Causes the Free-Run of the NE Clock

The ID of the internal clock source is the same as the ID of the external clock source, which results in the free-fun of the NE clock. When the setting of the internal clock source ID is cancelled, the fault is rectified.

Product

Fault Type

  • Time synchronization
  • S1_SYN_CHANGE
  • LTI

Symptom

The SL64 board is installed in both slot 8 and slot 11 of the OptiX OSN 3500. The OptiX OSN 3500 and the OptiX OSN 7500 are interconnected. The cross-connect board of each device reports the S1_SYN_CHANGE and LTI alarms.
  • The clock configuration of the OptiX OSN 3500 is as follows:
    • The clock source traced by the line board is obtained from another device, and the priority of the external clock source is higher than the priority of the internal clock source.
    • The reversion mode of the high-priority clock source is set to automatic reversion.
    • The clock quality is set to Automatic Extraction.
    • Protection Status is set to Star Extended SSM Protocol.
    • The clock ID of the line board is not set.
    • The ID of the internal clock source is set to 6.
    • All the clock sources are in the normal state.
  • The clock configuration of the Optix OSN 7500 is as follows:
    • The external clock source exists.
    • No clock ID for either the external clock source or the internal clock source is set.
    • The clock synchronization source is provided by the clock source of the line board with a higher priority.

Cause Analysis

The OptiX OSN 3500 and the OptiX OSN 7500 are located on the same network, and the clocks of the entire network are synchronized with the external clock source of the device outside the network. The ID of the external clock source is 6, which conflicts with the ID of the internal clock source of the Optix OSN 3500. In this case, when the OptiX OSN 3500 detects the signals of the external clock source, after checking the ID of the external source, the OptiX OSN 3500 regards the signals as the internal clock signals. Therefore, to prevent the clock tracing loop, the clock of the OptiX OSN 3500 enters the free-run mode.

Procedure

  1. In the T2000 main topology, right-click the NE icon of the OptiX OSN 3500, and then choose NE Explorer.
  2. Choose Configuration > Clock > Clock Subnet Configuration from the Function tree.
  3. Click the Clock Subnet tab.
  4. Set Internal Clock Source.
     NOTE:
    If the device does not have an external clock source, set Internal Clock Source to (None). If the ID of the internal clock source is required to be set, make sure that the ID is different from the clock IDs of other devices.
  5. Click Apply. In the Operation Result dialog box, click Close.

Failure of the Test Frame Due to the Inconsistent Bearing Modes

When the Ethernet boards are interconnected, the test frame cannot function normally due to the inconsistent bearing modes.

Product

Symptom

When the N2EFS4 board is interconnected to the N1EFT8/R1EFT4/N1EFT8A board, the receive end fails to receive any test frame, and the transmit end fails to receive any response frame.

Cause Analysis

The N2EFS4 board transmits the test frames in Ethernet bearing mode, but the N1EFT8/R1EFT4/N1EFT8A board supports GFP bearing mode only.

Procedure

  1. Before enabling the function of the test frame, check whether the bearing modes at the two interconnected ends are consistent.
    • For the board whose bearing mode of the test frame can be set and queried, you just need to query on the T2000.
    • For the board whose bearing mode of the test frame cannot be set or queried, you need to refer to "Availability" in "Test Frame" of Features Description to obtain its bearing mode.
  2. If the bearing modes of the boards at the two interconnected ends are inconsistent, change the bearing modes to be the same so that the test frame can function normally.

Reference

Before transmitting test frames, ensure that the VC trunk port on which the function of the test frame is enabled, and that the corresponding cross-connection is configured.
The bearing modes of the boards at the two interconnected ends must be consistent. The boards in equipment of different versions may support different bearing modes for the test frame. See "Availability" in "Test Frame" of Features Description.


More related:

How to do when Occasional Hot Patch Installation Failures?

Service Becoming Unavailable When the IMA Protocol and VPRing Protocol Are Configured at the Same Time

Service becoming unavailable when the IMA protocol and VPRing protocol are configured at the same time. You need to rectify the faults at the opposite end.

Product

Fault Type

Configuration_Problem

Symptom

If the IMA protocol is configured for symmetrical operation, and if the VPRing protocol is configured for single-ended switching, the services are unavailable in the case of hybrid configuration.
The services become unavailable.

Cause Analysis

The IMA protocol is configured for symmetrical operation, and the VPRing is configured for 1+1 or 1:1 single-ended switching. In this case, if a switching event occurs to the VPRing protocol, and if the IMA protocol detects the failure for the opposite end to receive signals, the local end stops transmitting cells.

Procedure

  1. Rectify the faults at the opposite end.

Wednesday, June 1, 2016

The SC2 Board Reports the CRC4_CROSSTR Alarm

The SC2 board reports the CRC4_CROSSTR alarm due to the board faulty.

Product

OptiX Metro 6040

Fault Category

Optical Supervisory Channel Unit
CRC4_CROSSTR

Symptom

The SC2 board in the OptiX Metro 6100 reports the CRC4_CROSSTR alarm.

Cause Analysis

The main causes may be the abnormal received optical power and the fault in the fiber or optical connectors.

Procedure

  1. The received optical power of the SC2 board is normal (The receiver sensitivity of the SC2 board is -48V.), whereas the SC2 board reports the alarm.
  2. The fault persists even when the fibers and connectors at the RM1 interface of the SC2 board are cleaned.
  3. Replace the SC2 board, and the fault is cleared. This indicates that the RM1 interface of the SC2 board is faulty.

The WXCP Protection Configured for the LOG Board Is Invalid

The WXCP protection configured for the LOG board is invalid due to the configured attributes of the board.

Product

OptiX Metro 6040

Fault Category

Protection

Symptom

The LOG board is configured with the correct WXCP protection.
During a protection switching test, services are interrupted because there is no protection channel to which the services can be switched; however, no alarms are reported to the T2000.
Check whether the protection configuration is correct.
If you delete the protection group and then configure a new one, the fault persists.

Cause Analysis

The WXCP protection configured for the LOG board is invalid due to the configured attributes of the board.

Procedure

  1. Check the LOG board of the protection group.
    1. In the NE Explorer, select the LOG board to be checked.
    2. Select Configuration > WDM Interface from the Function Tree.
    3. Click the Advanced Attributes tab.
    4. Check whether the Max Packet Length is 9800.
  2. In this case, set the value of this parameter to 1511.
  3. Because the value of the parameter cannot be changed, set the LOG board.
  4. After the LOG board is reset, the value of the parameter is displayed as 9800.
  5. Test whether the fault is cleared. If the fault is cleared, the WXCP protection becomes valid.

The Input Optical Power of the OTU Board Is Abnormal Due to a Fault of the OPU Board

The input optical power of the OTU board is abnormal due to a fault of the OPU board.

Product

OptiX Metro 6040

Fault Category

Optical Power Abnormity
Optical Amplifier Unit

Symptom

In a single-channel ring network, the input optical power of an OTU board drops from 0 dBm to -7 dBm, -15 dBm, or -62 dBm.
This ring network bears the SDH service and is configured with the multiplex section protection (MSP).

Cause Analysis

The launched optical power of the opposite OTU is abnormal, or the line amplifier unit is faulty.

Procedure

  1. By checking whether there are abnormal alarms against the input optical power of the opposite OTU board, you can find that the parameters of the opposite OTU board are proved normal. This indicates that the launched optical power of the opposite OTU is normal.
  2. The input and output optical power of the opposite amplifier board are also checked normal.
  3. The input and output optical power of the local amplifier board, however, are checked abnormal. The input optical power of the local amplifier board is constant, whereas the output optical power of the local amplifier board is abnormal. This indicates that the local amplifier board is faulty.
  4. After you replace the local amplifier board, the system is restored.

Reference Information

  • When you find that the output optical power of the local OTU is abnormal, check the following items:
    • Input and output optical power of the opposite OTU board
    • Input and output optical power of the opposite amplifier board
    • Input and output optical power of the local amplifier board
  • If the anomaly of optical power occurs at random, perform the following steps:
    • Check whether any fiber jumper is loose or bent.
    • Clean the fibers and connectors.
    • Perform an optical time domain reflectometer (OTDR) test under the customer's consent.



Monday, May 30, 2016

Analysis of the POWER_FAIL Alarm on the OptiX OSN 6800 and Solution

The SCC board reports the POWER_FAIL alarm due to a battery failure.

Product

OptiX OSN 3800

Fault Type

System and Communication Unit
POWER_FAIL

Symptom

During commissioning of the OptiX OSN 6800 in a pilot project, the SCC board reports the POWER_FAIL alarm.
Alarm Parameters (hex): 0x05 0xff 0xff 0xff 0xff

Cause Analysis

The OptiX OSN 6800 is new equipment and several OptiX OSN 6800 NEs have this alarm. It is suspected that the power module is faulty.
After cutting off the power of the OptiX OSN 6800 then power on, the equipment time and date information is lost and changes to the initial time and date, that is 1990-01-01 00:00:00. Then, the battery on the SCC may be faulty.

Procedure

  1. Remove the SCC board and check the jumper that controls the battery. This jumper is found in an incorrect state.
  2. Change the state of the jumper so that the battery works.
  3. Insert the SCC. The POWER_FAIL alarm is cleared.
  4. Reset the date and time.
  5. Reset the equipment and the time and date information is not lost. The problem is solved.

Reference Information

The jumper is to be set before delivery, the setting on sit is not required to be fixed normally.


More related:

When Interruption of Existing Services on Some Data Boards of OSN Products