Abstract:
The MA5600T reports digital alarms because the original ESC values are different from the actual tested values. 
Product LineAccess network    Product Model:MA5600T
[Fault Description]
Trigger conditions:
The control board is connected to the normal ESC and the software version is upgraded to V800R008C01SPC100. 
Symptom:
The ESC generates alarms and the indicator (red) blinks one second on and one second off. The related information is as follows:
huawei(config-if-h801esc-0)#display esc alarm                                   
                                                                                
  EMU ID: 0                             ESC alarm information                   
  ----------------------------------------------------------------------------  
  AnalogID Name                 Alarm   |AnalogID Name                 Alarm    
     0     Temperature          Normal  |   1     Input_-48V_0         Normal   
     2     Input_-48V_1         Low     |   3     Input_-48V_2         Normal   
     4     Input_-48V_3         Low     |   5     Temp_in              Low      
     6     -                    Normal  |   7     -                    Normal   
     8     -                    Normal                                          
  ----------------------------------------------------------------------------  
  DigitalID Name                Alarm   |DigitalID Name                Alarm    
     0     Wiring               Normal  |   1     Door0                Alarm    
     2     -                    Normal  |   3     -                    Normal   
     4     -                    Normal  |   5     -                    Normal   
     6     -                    Normal  |   7     Door_3               Normal   
     8     -                    Normal  |   9     Water_Alarm          Normal   
     10    Arrester 0           Alarm   |   11    Arrester 1           Alarm    
     12    Arrester 2           Alarm   |   13    Arrester 3           Alarm    
     14    SW11                 Alarm   |   15    SW12                 Alarm    
     16    SW21                 Alarm   |   17    SW22                 Alarm    
     18    SW31                 Alarm   |   19    SW32                 Alarm    
     20    SW41                 Alarm   |   21    SW42                 Alarm    
     22    Outer Sensor Power   Alarm   
----------------------------------------------------------------------------  

Identification method:
Query historical alarms. 
MA5600T(config)#display alarm history all                                       
{ <cr>|detail<K>|list<K>||<K> }:                                                
                                                                                
  Command:                                                                      
          display alarm history all
The following alarms are queried:
ALARM 1091 FAULT MINOR 0x15411005 ENVIRONMENTAL 2010-12-02 14:53:24+08:00     
  ALARM NAME  : The unnamed digital parameter is abnormal                       
  SRVEFF      : NSA                                                             
  PARAMETERS  : FrameID: 0    EMU ID:  0    Digital ID:  22    EMU Type:        
                H801ESC    Digital Name:  Outer Sensor Power                    
  DESCRIPTION : The digital parameter is inconsistent with the specified        
                valid value                                                     
  CAUSE       : The digital parameter is inconsistent with the preset valid     
                value                                                           
  ADVICE      : Check the object monitored by this digital parameter sensor     
  --- END                                                                       
                                                                                
  ALARM 1090 FAULT MINOR 0x15411005 ENVIRONMENTAL 2010-12-02 14:53:24+08:00     
  ALARM NAME  : The unnamed digital parameter is abnormal                       
  SRVEFF      : NSA                                                             
  PARAMETERS  : FrameID: 0    EMU ID:  0    Digital ID:  21    EMU Type:        
                H801ESC    Digital Name:  SW42                                  
  DESCRIPTION : The digital parameter is inconsistent with the specified        
                valid value                                                     
  CAUSE       : The digital parameter is inconsistent with the preset valid     
                value                                                           
  ADVICE      : Check the object monitored by this digital parameter sensor     
  --- END                                                                       
                                                                                
  ALARM 1089 FAULT MINOR 0x15411005 ENVIRONMENTAL 2010-12-02 14:53:24+08:00     
  ALARM NAME  : The unnamed digital parameter is abnormal                       
  SRVEFF      : NSA                                                             
  PARAMETERS  : FrameID: 0    EMU ID:  0    Digital ID:  20    EMU Type:        
                H801ESC    Digital Name:  SW41                                  
  DESCRIPTION : The digital parameter is inconsistent with the specified        
                valid value                                                     
  CAUSE       : The digital parameter is inconsistent with the preset valid     
                value                                                           
  ADVICE      : Check the object monitored by this digital parameter sensor     
  --- END                                                                       
                                                                                
  ALARM 1088 FAULT MINOR 0x15411005 ENVIRONMENTAL 2010-12-02 14:53:24+08:00     
  ALARM NAME  : The unnamed digital parameter is abnormal                       
  SRVEFF      : NSA                                                             
  PARAMETERS  : FrameID: 0    EMU ID:  0    Digital ID:  19    EMU Type:        
                H801ESC    Digital Name:  SW32                                  
  DESCRIPTION : The digital parameter is inconsistent with the specified        
                valid value                                                     
  CAUSE       : The digital parameter is inconsistent with the preset valid     
                value                                                           
  ADVICE      : Check the object monitored by this digital parameter sensor     
  --- END                                                                       
                                                                                
  ALARM 1087 FAULT MINOR 0x15411005 ENVIRONMENTAL 2010-12-02 14:53:24+08:00     
  ALARM NAME  : The unnamed digital parameter is abnormal                       
  SRVEFF      : NSA                                                             
  PARAMETERS  : FrameID: 0    EMU ID:  0    Digital ID:  18    EMU Type:        
                H801ESC    Digital Name:  SW31                                  
  DESCRIPTION : The digital parameter is inconsistent with the specified        
                valid value                                                     
  CAUSE       : The digital parameter is inconsistent with the preset valid     
                value                                                           
  ADVICE      : Check the object monitored by this digital parameter sensor     
  --- END                                                                       
                                                                                
  ALARM 1086 FAULT MINOR 0x15411005 ENVIRONMENTAL 2010-12-02 14:53:24+08:00     
  ALARM NAME  : The unnamed digital parameter is abnormal                       
  SRVEFF      : NSA                                                             
  PARAMETERS  : FrameID: 0    EMU ID:  0    Digital ID:  17    EMU Type:        
                H801ESC    Digital Name:  SW22                                  
  DESCRIPTION : The digital parameter is inconsistent with the specified        
                valid value                                                     
  CAUSE       : The digital parameter is inconsistent with the preset valid     
                value                                                           
  ADVICE      : Check the object monitored by this digital parameter sensor     
  --- END                                                                       
                                                                                
  ALARM 1085 FAULT MINOR 0x15411005 ENVIRONMENTAL 2010-12-02 14:53:24+08:00     
  ALARM NAME  : The unnamed digital parameter is abnormal                       
  SRVEFF      : NSA                                                             
  PARAMETERS  : FrameID: 0    EMU ID:  0    Digital ID:  16    EMU Type:        
                H801ESC    Digital Name:  SW21                                  
  DESCRIPTION : The digital parameter is inconsistent with the specified        
                valid value                                                     
  CAUSE       : The digital parameter is inconsistent with the preset valid     
                value                                                           
  ADVICE      : Check the object monitored by this digital parameter sensor     
  --- END                                                                       
                                                                                
  ALARM 1084 FAULT MINOR 0x15411005 ENVIRONMENTAL 2010-12-02 14:53:24+08:00     
  ALARM NAME  : The unnamed digital parameter is abnormal                       
  SRVEFF      : NSA                                                             
  PARAMETERS  : FrameID: 0    EMU ID:  0    Digital ID:  15    EMU Type:        
                H801ESC    Digital Name:  SW12                                  
  DESCRIPTION : The digital parameter is inconsistent with the specified        
                valid value                                                     
  CAUSE       : The digital parameter is inconsistent with the preset valid     
                value                                                           
  ADVICE      : Check the object monitored by this digital parameter sensor     
  --- END                                                                       
                                                                                
  ALARM 1083 FAULT MINOR 0x15411005 ENVIRONMENTAL 2010-12-02 14:53:24+08:00     
  ALARM NAME  : The unnamed digital parameter is abnormal                       
  SRVEFF      : NSA                                                             
  PARAMETERS  : FrameID: 0    EMU ID:  0    Digital ID:  14    EMU Type:        
                H801ESC    Digital Name:  SW11                                  
  DESCRIPTION : The digital parameter is inconsistent with the specified        
                valid value                                                     
  CAUSE       : The digital parameter is inconsistent with the preset valid     
                value                                                           
  ADVICE      : Check the object monitored by this digital parameter sensor     
  --- END                                                                       
                                                                                
  ALARM 1082 FAULT WARNING 0x15411113 ENVIRONMENTAL 2010-12-02 14:53:24+08:00   
  ALARM NAME  : The lightning arrester is faulty                                
  SRVEFF      : NSA                                                             
  PARAMETERS  : FrameID: 0    EMU ID:  0    Digital ID:  13    EMU Type:        
                H801ESC    Digital Name:  Arrester 3                            
  DESCRIPTION : Lightning arrester fails, affecting system lightning-proof      
                performance(digital parameter monitor)                          
  CAUSE       : The lightning arrester is faulty                                
  ADVICE      : Repair or replace the lightning arrester in time                
  --- END                                                                       
                                                                                
  ALARM 1081 FAULT WARNING 0x15411113 ENVIRONMENTAL 2010-12-02 14:53:24+08:00   
  ALARM NAME  : The lightning arrester is faulty                                
  SRVEFF      : NSA                                                             
  PARAMETERS  : FrameID: 0    EMU ID:  0    Digital ID:  12    EMU Type:        
                H801ESC    Digital Name:  Arrester 2                            
  DESCRIPTION : Lightning arrester fails, affecting system lightning-proof      
                performance(digital parameter monitor)                          
  CAUSE       : The lightning arrester is faulty                                
  ADVICE      : Repair or replace the lightning arrester in time                
  --- END                                                                       
                                                                                
  ALARM 1080 FAULT WARNING 0x15411113 ENVIRONMENTAL 2010-12-02 14:53:24+08:00   
  ALARM NAME  : The lightning arrester is faulty                                
  SRVEFF      : NSA                                                             
  PARAMETERS  : FrameID: 0    EMU ID:  0    Digital ID:  11    EMU Type:        
                H801ESC    Digital Name:  Arrester 1                            
  DESCRIPTION : Lightning arrester fails, affecting system lightning-proof      
                performance(digital parameter monitor)                          
  CAUSE       : The lightning arrester is faulty                                
  ADVICE      : Repair or replace the lightning arrester in time                
  --- END                                                                       
                                                                                
  ALARM 1079 FAULT WARNING 0x15411113 ENVIRONMENTAL 2010-12-02 14:53:24+08:00   
  ALARM NAME  : The lightning arrester is faulty                                
  SRVEFF      : NSA                                                             
  PARAMETERS  : FrameID: 0    EMU ID:  0    Digital ID:  10    EMU Type:        
                H801ESC    Digital Name:  Arrester 0                            
  DESCRIPTION : Lightning arrester fails, affecting system lightning-proof      
                performance(digital parameter monitor)                          
  CAUSE       : The lightning arrester is faulty                                
  ADVICE      : Repair or replace the lightning arrester in time                
  --- END  


[Root Cause]
Whether the H801ESC dry contact generates alarms depends on alarm detection and control board configurations. 
By default, the H801ESC dry contact does not generate alarms if a high level is used. 
If the control board is configured to generate an alarm in low level, the H801ESC dry contact generates an alarm when it detects a high level. 
If the control board is configured to generate an alarm in low level, the H801ESC dry contact does not generate an alarm when it detects a low level. 
The default configuration of the control board is incorrect. As a result, H801ESC generates alarms continuously. 
The configurations are as follows: 
      10    Arrester 0                1    |   11    Arrester 1           1       
      12    Arrester 2                1    |   13    Arrester 3           1       
      14    SW 11                         |   15    SW 12                 1       
      16    SW 21                      1    |   17    SW 22                 1       
      18    SW 31                      1    |   19    SW 32                 1       
      20    SW 41                         |   21    SW 42                      
      22    Outer Sensor Power        
The detection values are as follows:
  10 Arrester 0             Alarm  0     |11 Arrester 1             Alarm  0            
   12 Arrester 2             Alarm  0     |13 Arrester 3             Alarm             
   14 SW 11                   Alarm  0     |15 SW 12                   Alarm  0            
   16 SW 21                   Alarm  0     |17 SW 22                   Alarm  0            
   18 SW 31                   Alarm  0     |19 SW 32                   Alarm  0            
   20 SW 41                   Alarm  0     |21 SW 42                   Alarm  0     
   22 Outer Sensor Power   Alarm  0                                        
                                     

[Impact and Risk]
The H801ESC dry contact generates alarms after the ESC is normal. For details about alarms, run the corresponding command to query alarms. 

[Measures and Solutions]
Recovery measures:
Run the following commands to modify default values of the ESC to recover the alarm. 
MA5600T(config-if-h801esc-0)#esc
{ analog<K>|digital<K> }:digital
{ digitalid<U><0,22> }:10
{ available-level<K>|digital-alarm<K>|monitor<K>|name<K> }:available-level
{ available-level<E><low-level,high-level> }:low-level
{ <cr>|digital-alarm<K>|monitor<K>|name<K> }:
  Command:
          esc digital 10 available-level low-level
  Send command to environment monitor board ,please waiting for the ack
MA5600T(config-if-h801esc-0)#
  Execute command successful
MA5600T(config-if-h801esc-0)#
! RECOVERY CLEARED 2010-12-02 19:03:25+08:00
  ALARM NAME :The lightning arrestor recovers from a fault -à The corresponding recovery alarm is generated.
  PARAMETERS :FrameID: 0    EMU ID:  0    Digital ID:  10    EMU Type:
  H801ESC    Digital Name:  Arrester 0
MA5600T(config-if-h801esc-0)#esc digital 11 available-level low-level
{ <cr>|digital-alarm<K>|monitor<K>|name<K> }:

  Command:
          esc digital 11 available-level low-level
  Send command to environment monitor board ,please waiting for the ack

MA5600T(config-if-h801esc-0)#
  Execute command successful

MA5600T(config-if-h801esc-0)#
! RECOVERY CLEARED 2010-12-03 10:59:14+08:00
  ALARM NAME :The lightning arrestor recovers from a fault
  PARAMETERS :FrameID: 0    EMU ID:  0    Digital ID:  11    EMU Type:
  H801ESC    Digital Name:  Arrester 1

MA5600T(config-if-h801esc-0)#esc digital 12 available-level low-level
{ <cr>|digital-alarm<K>|monitor<K>|name<K> }:

  Command:
          esc digital 12 available-level low-level
  Send command to environment monitor board ,please waiting for the ack

MA5600T(config-if-h801esc-0)#
  Execute command successful

MA5600T(config-if-h801esc-0)#
! RECOVERY CLEARED 2010-12-03 10:59:34+08:00
  ALARM NAME :The lightning arrestor recovers from a fault
  PARAMETERS :FrameID: 0    EMU ID:  0    Digital ID:  12    EMU Type:
  H801ESC    Digital Name:  Arrester 2

MA5600T(config-if-h801esc-0)#esc digital 13 available-level low-level
{ <cr>|digital-alarm<K>|monitor<K>|name<K> }:

  Command:
          esc digital 13 available-level low-level
  Send command to environment monitor board ,please waiting for the ack

MA5600T(config-if-h801esc-0)#
  Execute command successful

MA5600T(config-if-h801esc-0)#
! RECOVERY CLEARED 2010-12-03 10:59:45+08:00
  ALARM NAME :The lightning arrestor recovers from a fault
  PARAMETERS :FrameID: 0    EMU ID:  0    Digital ID:  13    EMU Type:
  H801ESC    Digital Name:  Arrester 3

MA5600T(config-if-h801esc-0)#esc digital 14 available-level low-level
{ <cr>|digital-alarm<K>|monitor<K>|name<K> }:

  Command:
          esc digital 14 available-level low-level
  Send command to environment monitor board ,please waiting for the ack

MA5600T(config-if-h801esc-0)#
  Execute command successful

MA5600T(config-if-h801esc-0)#
! RECOVERY CLEARED 2010-12-03 11:00:00+08:00
  ALARM NAME :The value of the unnamed digital parameter recovers to the
  normal range
  PARAMETERS :FrameID: 0    EMU ID:  0    Digital ID:  14    EMU Type:
  H801ESC    Digital Name:  SW11

MA5600T(config-if-h801esc-0)#esc digital 15 available-level low-level
{ <cr>|digital-alarm<K>|monitor<K>|name<K> }:

  Command:
          esc digital 15 available-level low-level
  Send command to environment monitor board ,please waiting for the ack

MA5600T(config-if-h801esc-0)#
  Execute command successful

MA5600T(config-if-h801esc-0)#
! RECOVERY CLEARED 2010-12-03 11:00:12+08:00
  ALARM NAME :The value of the unnamed digital parameter recovers to the
  normal range
  PARAMETERS :FrameID: 0    EMU ID:  0    Digital ID:  15    EMU Type:
  H801ESC    Digital Name:  SW12

MA5600T(config-if-h801esc-0)#esc digital 16 available-level low-level
{ <cr>|digital-alarm<K>|monitor<K>|name<K> }:

  Command:
          esc digital 16 available-level low-level
  Send command to environment monitor board ,please waiting for the ack

MA5600T(config-if-h801esc-0)#
  Execute command successful

MA5600T(config-if-h801esc-0)#
! RECOVERY CLEARED 2010-12-03 11:00:24+08:00
  ALARM NAME :The value of the unnamed digital parameter recovers to the
  normal range
  PARAMETERS :FrameID: 0    EMU ID:  0    Digital ID:  16    EMU Type:
  H801ESC    Digital Name:  SW21

MA5600T(config-if-h801esc-0)#esc digital 17 available-level low-level
{ <cr>|digital-alarm<K>|monitor<K>|name<K> }:

  Command:
          esc digital 17 available-level low-level
  Send command to environment monitor board ,please waiting for the ack

MA5600T(config-if-h801esc-0)#
  Execute command successful

MA5600T(config-if-h801esc-0)#
! RECOVERY CLEARED 2010-12-03 11:00:41+08:00
  ALARM NAME :The value of the unnamed digital parameter recovers to the
  normal range
  PARAMETERS :FrameID: 0    EMU ID:  0    Digital ID:  17    EMU Type:
  H801ESC    Digital Name:  SW22

MA5600T(config-if-h801esc-0)#esc digital 18 available-level low-level
{ <cr>|digital-alarm<K>|monitor<K>|name<K> }:

  Command:
          esc digital 18 available-level low-level
  Send command to environment monitor board ,please waiting for the ack

MA5600T(config-if-h801esc-0)#
  Execute command successful

MA5600T(config-if-h801esc-0)#
! RECOVERY CLEARED 2010-12-03 11:00:56+08:00
  ALARM NAME :The value of the unnamed digital parameter recovers to the
  normal range
  PARAMETERS :FrameID: 0    EMU ID:  0    Digital ID:  18    EMU Type:
  H801ESC    Digital Name:  SW31

MA5600T(config-if-h801esc-0)#esc digital 19 available-level low-level
{ <cr>|digital-alarm<K>|monitor<K>|name<K> }:

  Command:
          esc digital 19 available-level low-level
  Send command to environment monitor board ,please waiting for the ack

MA5600T(config-if-h801esc-0)#
  Execute command successful

MA5600T(config-if-h801esc-0)#
! RECOVERY CLEARED 2010-12-03 11:01:09+08:00
  ALARM NAME :The value of the unnamed digital parameter recovers to the
  normal range
  PARAMETERS :FrameID: 0    EMU ID:  0    Digital ID:  19    EMU Type:
  H801ESC    Digital Name:  SW32

MA5600T(config-if-h801esc-0)#esc digital 20 available-level low-level
{ <cr>|digital-alarm<K>|monitor<K>|name<K> }:

  Command:
          esc digital 20 available-level low-level
  Send command to environment monitor board ,please waiting for the ack

MA5600T(config-if-h801esc-0)#
  Execute command successful

MA5600T(config-if-h801esc-0)#
! RECOVERY CLEARED 2010-12-03 11:01:19+08:00
  ALARM NAME :The value of the unnamed digital parameter recovers to the
  normal range
  PARAMETERS :FrameID: 0    EMU ID:  0    Digital ID:  20    EMU Type:
  H801ESC    Digital Name:  SW41

MA5600T(config-if-h801esc-0)#esc digital 21 available-level low-level
{ <cr>|digital-alarm<K>|monitor<K>|name<K> }:

  Command:
          esc digital 21 available-level low-level
  Send command to environment monitor board ,please waiting for the ack

MA5600T(config-if-h801esc-0)#
  Execute command successful

MA5600T(config-if-h801esc-0)#
! RECOVERY CLEARED 2010-12-03 11:01:33+08:00
  ALARM NAME :The value of the unnamed digital parameter recovers to the
  normal range
  PARAMETERS :FrameID: 0    EMU ID:  0    Digital ID:  21    EMU Type:
  H801ESC    Digital Name:  SW42

MA5600T(config-if-h801esc-0)#esc digital 22 available-level low-level
{ <cr>|digital-alarm<K>|monitor<K>|name<K> }:

  Command:
          esc digital 22 available-level low-level
  Send command to environment monitor board ,please waiting for the ack

MA5600T(config-if-h801esc-0)#
  Execute command successful

MA5600T(config-if-h801esc-0)#
! RECOVERY CLEARED 2010-12-03 11:01:47+08:00
  ALARM NAME :The value of the unnamed digital parameter recovers to the
  normal range
  PARAMETERS :FrameID: 0    EMU ID:  0    Digital ID:  22    EMU Type:
  H801ESC    Digital Name:  Outer Sensor Power

Workarounds:
None
Preventive measures:
This issue had been resolved in MA5600T V800R008C01SPC101 in the first ten-day period of Dec. 2010.

[Rectification Scope and Time Requirements]
None

[Notice Expiration]
This notice automatically expires after MA5600T V800R008C01SPC101 is loaded