Service Interruption Caused by Resetting Cross-Connect Boards When NG-SDH Products Are in the NESTATE_INSTALL State


Product Line
Transport network
Product Family
Product Model
OSN 1500/OSN 2500/OSN 3500/OSN 3500 /OSN 7500
Release Date
2014-08-19
Severity
Major
Urgency
Non-urgent
Versions Involved
All R versions earlier than NG-SDH V100R010C03SPC200
NG-SDH V100R008C02SPH203 and later hot patch versions are not involved.
NG-SDH V100R008C02SPC500 and later V100R008 versions are not involved.
Devices Involved
Application Scope
China and outside China
Operation Category
Prewarning
Prewarning ID
21102
Operation Requirements
Learning and prevention
Expected Completion Date

Manpower Required

Contact Persons

Contact Person of the Product Line
Xu Kai (employee ID: 00287661)
Rectification Prime of the Regional Office

Rectification Prime of the Representative Office


Keywords:
NESTATE_INSTALL, service interruption, cross-connect board reset

[Problem Description]
Trigger conditions:
This problem occurs if all the following conditions are met:
1. An NE is in the NESTATE-INSTALL state.
2. The active cross-connect board of the NE is warm/cold reset, or the standby
cross-connect board is warm/cold reset and then a switchover occurs between the active and
standby cross-connect boards.

Symptom:
All services on the NE are interrupted.

Identification method:
A cross-connect board of an NE is reset when the NE is in the NESTATE_INSTALL state.

[Root Cause]
When an NE is in the NESTATE_INSTALL state, it does not apply service configurations to cross-connect boards. However, if a cross-connect board is reset when the NE is in the NESTATE_INSTALL state, the NE automatically adds a corresponding logical board and applies null configuration to the reset cross-connect board. If the reset is performed on the active cross-connect board, services are interrupted. If the reset is performed on the standby cross-connect board and then a switchover occurs between the active and standby cross-connect boards, services are interrupted.

[Impact and Risk]
When an NE is in the NESTATE_INSTALL state and its cross-connect boards are reset, all services may be interrupted.

Measures and Solutions
Recovery measures:
For a non-ASON NE, download configuration data from the network management system (NMS) to recover services.
For an ASON NE, restore NE databases, and then reset service boards (such as cross-connect boards and line boards) to recover services. Alternatively, recover services by following the corresponding disaster recovery guides.

Preventive measures:
When an NE is in the NESTATE_INSTALL state, do not reset cross-connect boards, configure new services, or issue verification commands.

Solution:
Upgrade the NE to one of the following versions to solve the problem:
NG-SDH V100R008C02SPH203 or a later hot patch version
NG-SDH V100R008C02SPC500 or a later V100R008 version
NG-SDH V100R010C03SPC200 or a later version

Material handling after replacement:
N/A

[Inspection Tool Applicable or Not]
N/A

[Rectification Scope and Time Requirements]
N/A

[Rectification Instructions]
N/A

[Attachment]
N/A