The limitations on the Optical Line Protection Usage of the OLP Boards for NG WDM Equipment

There are the following problems when OLP boards are used to provide optical line protection:When the FIU board is deployed on the line, the optical line protection group using the TN11OLP01/TN11OLP02/TN12OLP01 board can only protect the optical transmission section (OTS), and it cannot protect the optical multiplex section (OMS).When the SFIU board is deployed on the line to provide single-fiber bidirectional transmission, the optical line protection group must use the TN12OLP04 board. 
Product LineTransport network product line     Product Family: DWM
Product Model:   OptiX OSN 6800            OptiX OSN 8800

[Problem Description]

        Trigger condition:
Problem 1: The TN11OLP01/TN11OLP02/TN12OLP01 board cannot be used to protection the OMS.
This problem occurs in either of the following scenarios:
During network deployment, the TN11OLP01/TN11OLP02/TN12OLP01 board is equipped with OMS optical line protection.
On the live network, the TN11OLP01/TN11OLP02/TN12OLP01 board is originally equipped with OTS optical line protection, which is later changed to OMS optical line protection.
Figure 1 OTS optical line protection networking


Figure 2 OMS optical line protection networking

Problem 2: When the SFIU board is deployed on the line to provide single-fiber bidirectional transmission, the optical line protection group must use the TN12OLP04 board.
Symptom:
Symptom of problem 1: When the line is normal, the OMS optical line protection group configured using the TN11OLP01/TN11OLP02/TN12OLP01 board frequently perform protection switching sometimes.
Symptom of problem 2: When the SFIU board is deployed on the line to provide single-fiber bidirectional transmission, the optical line protection group must use the TN12OLP04 board
Identification method:
For problem 1: Check whether the TN11OLP01/TN11OLP02/TN12OLP01 board is equipped with OMS optical line protection.
For problem 2: When the SFIU board is deployed on the line to provide single-fiber bidirectional transmission, the optical line protection group must use the TN12OLP04 board

[Root Cause]

For problem 1: In the OMS optical line protection scenario, the input power for the RI1 and RI2 ports on the TN11OLP01/TN11OLP02/TN12OLP01 board will easily exceed +7 dBm. Therefore, the TN11OLP01/TN11OLP02/TN12OLP01 board cannot be used to protect an OMS.

In an OTS optical line protection scenario, the input power for the RI1 and RI2 ports on the TN11OLP01/TN11OLP02/TN12OLP01 board must be less than or equal to +7 dBm.
For problem 2: NA

[Impact and Risk]

Impact and risk brought by problem 1: When the line is normal, the OMS optical line protection group configured using the TN11OLP01/TN11OLP02/TN12OLP01 board may perform protection switching frequently.
Impact and risk brought by problem 2: When the SFIU board is deployed on the line to provide single-fiber bidirectional transmission, the optical line protection group must use the TN12OLP04 board

[Measures and Solutions]

Recovery measures:
For problem 1: None
For problem 2: When the SFIU board is deployed on the line to provide single-fiber bidirectional transmission, the optical line protection group must use the TN12OLP04 board
Workarounds:
None
Preventive measures:
For problem 1, take the following preventive measures:
− When using the TN11OLP01/TN11OLP02/TN12OLP01 board to configure optical line protection, select the OTS scenario.
− If OMS optical line protection must be configured, use the TN12OLP03.
For problem 2: When the SFIU board is deployed on the line to provide single-fiber bidirectional transmission, the optical line protection group must use the TN12OLP04 board.
If the DCP and OLP boards used on the live network have the issues mentioned in [TN-P-201247] Notice on Precaution for Abnormal Switching on the VER.F DCP and OLP Boards That Use an Earlier Version Logic-20120910-A, perform an upgrade by following the instructions in this notice. 

[Attachment]

The following table provides the protection types supported by the OLP boards for NG WDM equipment.