How to Clear the LASER_HAZARD_WARNING Alarms Reported on Certain OBU and OAU Boards After an Upgrade of Software

After a software upgrade, certain OBU and OAU boards report the LASER_HAZARD_WARNING alarms, which are confusing for users. To avoid such an alarm, configure the IPA feature or disable monitoring of this alarm.

Fault Type

Optical Amplifier Unit
LASER_HAZARD_WARNING

Symptom

During deployment for a project involving the OptiX BWS 1600G, the NE software of version 5.8.5.41 is upgraded to version 5.8.7.12 by means of package loading so that the NE software supports the 40G single wavelength feature. After the upgrade is complete, the E50BU and E50AU boards at certain stations report the LASER_HAZARD_WARNING alarms.

Cause Analysis

The LASER_HAZARD_WARNING alarm (an alarm for the hazard of the output optical power of the laser) indicates that the output optical power of the amplifier board reaches Class 3. Optical power at Class 3 may result in personal injuries (the board can reach Class 3 but may not reach currently). This amplifier board is not configured with the IPA feature. Thus the NE software reports this alarm.
The maximum output optical power of a laser at Class 3 ranges from 21.3 dBm to 27 dBm. The maximum output optical power of a laser at Class 4 ranges as high as 27 dBm.
  • The NE software of version 5.8.7.12 and a later version supports the LASER_HAZARD_WARNING alarm.
  • The ROP, RPA, RPC, or HBA board reports the LASER_HAZARD_WARNING alarm if the NE software report the LASER_HAZARD_WARNING alarm.
  • In the case of an OAU, OBU, or OPU board, check whether the output optical power of the board reaches Class 3. The board reports the alarm if the output optical power of the board reaches Class 3.
    • An E3OAUC05 or OBUC05 board of version 3.31 and a later version supports the LASER_HAZARD_WARNING alarm.
    • An E4OAUC05 or OBUC05 board of version 4.21 and a later version supports the LASER_HAZARD_WARNING alarm.
    • An E5OAUC05 or OBUC05 board of version 5.13 and a later version supports the LASER_HAZARD_WARNING alarm.

Procedure

  1. The LASER_HAZARD_WARNING alarm can be cleared by configuring the IPA feature on the amplifier board or configuring suppression of the LASER_HAZARD_WARNING alarm. The alarm may result in personal injuries. Therefore, you need to use the suppression function with caution.

Result

The problem is resolved.

Thursday, July 14, 2016

When Failed to Create ATM Services

ATM services fail to be created, thus failing to realize the protection. You need to add the two connections into the protection group.

Fault Type

Configuration_Problem

Symptom

After you create two connections that have the same source but different sinks, or that have the same sink but different sources, the service of a connection fails to be created.
The service fails to be created. The protection fails to be achieved accordingly.

Cause Analysis

The second connection takes effect only after you add the two connections that have the same source but different sinks, or that have the same sink but different sources into the protection group.

Procedure

  1. Add the two connections into the protection group.

How to do when Mismatching Between MA Groups and Associated VCTRUNKs, Hence Causing the Binding Failure?

IMA groups fail to be bound with associated VCTRUNKs. You need to configure IMA groups to match with associated VCTRUNKs.

Fault Type

Configuration_Problem

Symptom

The principle of binding VCTRUNKs is met, but VCTRUNKS fail to be bound.

Cause Analysis

Mutual check relation exists between IMA groups and associated VCTRUNKs.

Procedure

  1. If IMA groups are symmetrically configured, make sure that the mapping VCTRUNKs are symmetrical.
  2. If VCTRUNKs are nonsymmetrical, make sure that the mapping IMA groups are nonsymmetrical.

Failing to Create the 622 Mbit/s Service

The ATM 622 Mbit/s service fails to be created. You need to adjust the VCTRUNK that is bound with VC-4.

Fault Type

Configuration_Problem

Symptom

The 622 Mbit/s service fails to be created.

Cause Analysis

The four bound VC4 virtual connections are in the first ATM processing unit. The source end or sink end of the created connection belong to the same external port. The bandwidth used at the source end and sink end is 622 Mbit/s x 2 = 1244 Mbit/s, which exceeds the maximum bandwidth of a single ATM processing unit.

Procedure

  1. Delete the VCTRUNK that is bound with VC4 timeslots 1 -4.
  2. Set up the VCTRUNK that is bound with VC4 timeslots 5 -8.

Wednesday, July 13, 2016

The Maximum Optical Power that an LSH/APC and an FC/UPC Connector can Withstand is 33 dBm and 25 dBm Respectively

The maximum optical power that an LSH/APC and an FC/UPC connector can withstand is 33 dBm and 25 dBm respectively.

Product


Fault Type

Others

Symptom

Among the WDM products, the Raman amplifier outputs high optical power. Thus an LSH/APC connector is recommended for a Raman amplifier. In addition, adopt fiber splicing, whenever feasible, on the ODF to prevent the interface section from being burned out by laser radiation. When interface section is burned out, reflected laser radiation may burn the amplifier.
Therefore, pay special attention to the range of optical power that various connectors can withstand.

Cause Analysis

  • The fiber patch cord with an LSH/APC connector can withstand optical power as high as 2000 mw, that is, 33 dBm.
  • The fiber patch cord with an FC/UPC connector can withstand optical power as high as 300 mw, that is, 25 dBm.

Procedure

  1. None.

Result

The problem is resolved.

MTU Supported by an LBF Board for the 10G LAN Service on Client Side Cannot Be Configured

The MTU supported by an LBF board for the 10G LAN service on client side cannot be configured.

Product

Fault Type

Optical Transponder Unit

Symptom

When the WDM interface attributes on an E3LBFS board are configured by using the NMS, the Maximum Packet Length parameter cannot be configured after Service Type is set to 10GE(LAN). By default, Maximum Packet Length is 1518.

Cause Analysis

The possible causes of the preceding problem are as follows:
  • An E2LBF board supports client-side services in two modes, that is, Flow Control Mode and Transparent Transmission Mode. In Flow Control Mode, the MTU is 9600 and cannot be changed. In Transparent Transmission Mode, the MTU is invalid.
  • An E3LBF board supports the client-side services only in Transparent Transmission Mode. In this mode, the board transfers service packets transmitted from the client side without limits.

Procedure

  1. None.

Result

The problem is resolved.

How to Configure Two TMX Boards in a Client-Side 1+1 Protection Group Through an SCS Board

How to configure two TMX boards in a client-side 1+1 protection group through an SCS board.

Fault Type

Protection

Symptom

When configuring two TMX boards in a client-side 1+1 protection group through an SCS board, how to configure the attributes of the WDM interface ?
It is required to determine whether the Laser Status parameter should be set to Open and Automatic Laser Shutdown to Disabled, or Laser Status should be set to Open and Automatic Laser Shutdown to Enabled.
Is the laser on the TMX board closed automatically when the TMX boards work with an SCS board?

Cause Analysis

The setting of the Automatic Laser Shutdown parameter of the port on the WDM side or the client side is irrelevant to the protection. Normally, when the attributes of the WDM interface on the TMX board are configured through an OTU board, the Automatic Laser Shutdown parameter of the port on the WDM side is set to Disabled and Automatic Laser Shutdown of the port on the client side is set to Enabled.
After a client-side 1+1 protection group is configured, the status of the client-side laser is controlled by the status of protection group.

Procedure

  1. None.

Result

The problem is resolved.