Function Description
Operation Administration & Maintenance (OAM) is an effective method used to reduce the cost of network maintenance. The MA5680T/MA5683T/MA5608T connects to the access convergence network through the upstream network port. OAM management packets start from or terminate at the upstream network port. You can perform OAM configuration management through NMS. NMS maintains the network based on the reported information of OAM status and alarms.Function
This command is used to query the configuration of the connectivity fault
management (CFM) MIP.
Format
display cfm mip vlan vlanid
frameid/slotid/portid [ gemportid
gemportid-value ] [ vlantag1 vlantag1-value [
vlantag2 vlantag2-value ] ]
display cfm mip vlan vlanid { frameid/slotid/portid | l2vpn }
display cfm mip vlan vlanid frameid/slotid/portid [ vpi vpi vci vci ] [ vlantag1 vlantag1–value [ vlantag2 vlantag2–value ] ]
display cfm mip vlan vlanid { frameid/slotid/portid | l2vpn }
display cfm mip vlan vlanid frameid/slotid/portid [ vpi vpi vci vci ] [ vlantag1 vlantag1–value [ vlantag2 vlantag2–value ] ]
Parameters
Parameter | Description | Value |
---|---|---|
vlan vlanid | Indicates that the configuration of the CFM MIP is queried by VLAN. | Numeral type. Range: 1-4094. |
frameid/slotid/portid | Indicates the subrack ID, slot ID, and port ID. Enter a slash (/) between the subrack, slot, and port IDs. | Please see Differences Between Shelves. |
gemportid gemportid-value | Indicates the ID of the GEM port. To create a maintenance end point (MEP) for a GEM port, use this parameter. | Numeral type. Range: 128-3999. |
vpi vpi | Indicates the VPI value to be entered. It is used to identify a user when used with the VCI. |
Numeral type. Range:
|
vci vci | Indicates the VCI value to be entered. It is used to identify a user when used with the VPI. |
|
vlantag1 vlantag1-value | Indicates VLAN tag 1, representing an outer VLAN receiving or sending packets. | Numeral type. Range: 1-4095. |
vlantag2 vlantag2-value | IIndicates VLAN tag 2, representing an inner VLAN receiving or sending packets. | Numeral type. Range: 1-4095. |
l2vpn | Indicates the MPLS Layer 2 virtual channel. | - |
Modes
Privilege mode
Level
Operator level
Usage Guidelines
None
Example
To query the configuration of the CFM MIP of VLAN 2 in the 0/19/0 port, do as follows:
huawei#display cfm mip vlan 2 0/19/0
MIP Level : 0
MIP MAC : 00E0-FC00-0142
System Response
- The system displays the queried result when the command runs successfully.
- The following table describes the parameters in response to this
command.
Parameter Description MIP level Indicates the MIP level. You can run the cfm md command to set the parameter. MIP MAC Indicates the MIP MAC address. When you run the cfm disable command to disable the CFM function, the system displays "-".