Function Description

Operation Administration & Maintenance (OAM) is an effective method used to reduce the cost of network maintenance. The MA5680T/MA5683T/MA5608T connects to the access convergence network through the upstream network port. OAM management packets start from or terminate at the upstream network port. You can perform OAM configuration management through NMS. NMS maintains the network based on the reported information of OAM status and alarms.

Function

This command is used to query the information about the connectivity fault management (CFM) database.

Format

display cfm ccm-database

Parameters

None

Modes

Privilege mode

Level

Operator level

Usage Guidelines

None

Example

To query the information about the CFM database, do as follows:
huawei#display cfm ccm-database                                 
  MAC Address       VLAN ID    PORT               GEMPORTID/VPI VCI      
  -----------------------------------------------------------------------
  00E0-FC00-1111    100        0/3/0              96                  
  -----------------------------------------------------------------------
  Total: 1

System Response

  • The system displays the queried result when the command runs successfully.
  • The following table describes the parameters in response to this command.
    Parameter Description
    MAC Address Indicates the MAC address.
    VLAN ID Indicates the associated VLAN ID.
    Port Indicates the port ID. When the type of the port where the MEP is located is L2VPN, the corresponding port ID is not available and "L2VPN" is displayed.
    GEMPORTID/VPI Indicates the GEM port ID when GEMPORTID is displayed in querying a GPON port. Indicates the virtual path when VPI is displayed in querying an ATM port.
    VCI Indicates the virtual channel when VCI is displayed in querying an ATM port.