Monday, August 8, 2016

display io-packetfile information

Function

This command is used to query the information about the board software package that is already loaded to the system. To check whether the board software version matches the software version of the control board, or whether the board software version matches the board hardware, run this command.

Format

display io-packetfile information

Parameters

None

Modes

Level

Operator level

Usage Guidelines

When the query shows that the board software version is inconsistent with the matching board software version described in the Release Notes, you can run the load packetfile command to load the matching program package file.

Example

To query the information about the board software package, do as follows:
huawei#display io-packetfile information
  Version of the board software packetfile:MA5600V800R015C10                    
  Board software saved in mainboard:
  ---------------------------------------------------------------------------
  Index  File Type                 Version                File Length
  ---------------------------------------------------------------------------
   0     CPMU0107 PROGRAM          205                    186112
   1     PMU02B03 PROGRAM          205                    141440
   2     EPMU0203 PROGRAM          109                    57600
   3     H801ESC PROGRAM           112                    18944
   4     FAN PROGRAM               160                    7936
   5     H801FCBC PROGRAM          109                    7808
   6     H801FCBH PROGRAM          103                    61056
   7     H801FCBG PROGRAM          108                    60416
   8     H801FCBI PROGRAM          104                    59136
   9     H801FMCA PROGRAM          112                    13184
   10    SMU01B PROGRAM            304                    199552
   11    SMU01D PROGRAM            303                    210688
   12    H801HEUD PROGRAM          114                    122368
   13    H801BIUA BASE BIOS        125                    12288
   14    H801BIUA PROGRAM          141                    41984
   15    H801BIUA CPLD             102                    13952
   16    H801CITD PROGRAM          168                    49280
   17    H801CITD EXT BIOS         118                    8704
---- More ( Press 'Q' to break ) ----       

System Response

  • The system displays the queried result when the command runs successfully.
  • The following table describes the parameters in response to this command.
    Parameter Description
    Version of the board software packetfile Indicates the version of the control board software.
    Board software saved in mainboard Indicates the board software information saved on the control board.
    Board software saved in board Indicates the board software information saved on the board.
    Index Indicates the index.
    File Type Indicates the type of the file.
    Version Indicates the version of the board software.
    File Length Indicates the file length. Unit: byte.
    Status of the board software packetfile Indicates the board software status. It can be active or deactive.
  • For more information about the error message that the system displays against a command entered with incorrect syntax, 