Logical Board of SLQ16 Cannot Be Added on T2000

The logical board of the SLQ16 cannot be created on the T2000. This fault is rectified after the logical board of the cross-connect board is changed.

Fault Type

Others

Symptom

A customer fails to add the logical board of the SLQ16 on the OptiX OSN 3500, and the customer mentions that the cross-connect board is changed from the UXCSA to the SXCSA on site.

Cause Analysis

The SLQ16 is applicable only to the OptiX OSN 3500 of 200 Gbit/s cross-connect capacity. If the cross-connect capacity decreases to 40 or 80 Gbit/s, the SLQ16 fails to work normally. The SXCSA has the board version replacement function. If the original logical board is the UXCSA, the system considers that the cross-connect board is the UXCSA by default, rather than the SXCSA. As a result, the logical board of the SLQ16 cannot be added.

Procedure

  1. Query the physical and logical boards in slots 9 and 10 on the T2000. All the physical and logical boards are the UXCSA.
  2. This is because the customer does not change the logical cross-connect board after the replacement of the physical cross-connect board. Change the logical cross-connect board to the SXCSA. Then, the logical board of the SLQ16 is added successfully.