Thursday, September 22, 2016

ONT Voice Service Management----display mass-sip-alarm

Function

This command is used to query the information about the ONT SIP registration group fault alarm. To query the number of ONT SIP registration alarms, and status and threshold of the ONT SIP registration group fault alarm, run this command.

Format

display mass-sip-alarm

Parameters

None

Modes

Privilege mode, SCUN,SCUK

Level

Operator level

Usage Guidelines

  • When the number of ONT SIP registration fault alarms is greater than the threshold of the ONT SIP registration group fault alarm, the system reports the ONT SIP registration group fault alarm.
  • When the number of ONT SIP registration fault alarms decreases to a value that is smaller than the threshold of the ONT SIP registration group fault alarm, the system does not immediately generates the group fault clear alarm. Instead, the system waits for 10 minutes or waits until all the ONT SIP users are successfully registered and then reports the clear alarm.
  • You can run the mass-sip-alarm threshold command to set the threshold of the ONT SIP registration group fault alarm.

Example

To query the information about the ONT SIP registration group fault alarm, do as follows:
huawei#display mass-sip-alarm
  Configuration:
  ------------------------------------------------------------------------------
   Mass alarm threshold: 100
  ------------------------------------------------------------------------------

  Current Alarm Status:
  ------------------------------------------------------------------------------
   Alarm Name                        Alarm Number    Mass Alarm
  ------------------------------------------------------------------------------
   ONT SIP user authenticate fail    6               N
   ONT SIP user register timeout     6               N
   ONT SIP user register fail        6               N
  ------------------------------------------------------------------------------

System Response

  • The system displays the queried result when the command runs successfully.
  • The following table describes parameters in response to this command.
    Parameter Description
    Mass alarm threshold Indicates the threshold of the ONT SIP registration group fault alarm.
    Alarm Name Indicates the alarm name.
    Alarm Number Indicates the number of active alarms in the system.
    Mass Alarm Indicates whether the group fault alarm is reported.
  • For more information about the error message that the system displays against a command entered with incorrect syntax